Main page content
Tempo 555B Fiber Optic Power Meter performs insertion Loss and Link Loss Testing. Tempo 555B 1mm InGaAs fiber optic power meter is a rugged high quality general purpose instrument suitable for many fiber optic measurement applications. Paired with a TEMPO 250 Series LED source or 260 Series laser source, the 555B fiber optic power meter is ideal for insertion loss testing of multi-mode and single-mode fiber optic cables and connectors. Tempo 555B fiber optic power meter can also be used for link loss testing of installed cable plants. Output Power Measurements.
Optical Power Meter model 556MT made by Tempo. Pair with an LED source to test insertion loss of multimode MT-RJ fiber optic cables and connectors or use independently to perform link loss testing of installed cable plants.
Tempo 557B Silicon Optical Power Meter performs Insertion Loss and Link Loss Testing. The 557B 3 x 3.5 mm Si optical power meter is a general purpose instrument suitable for conducting fiber optic measurements on systems and networks based on a single-mode, multimode, plastic, and large core glass optical fibers. The 635, 780, and 850nm calibration wave-lengths are optimized for fiber optic systems incorporating near-infrared and visible light sources. Output Power Measurements.
AEMC CA811 Handheld Light Meter is designed for simple single-hand operation with an ergonomic case, large 2000 count illuminated LCD, data freeze feature, and optical sensors that are designed to match the response of the human eye.
AEMC CA813 Handheld Light Meter is designed for simple single-hand operation with an ergonomic case, large 2000 count illuminated LCD, data freeze feature, and optical sensors that are designed to match the response of the human eye.
Tempo 253B 650nm LED Source performs multimode insertion loss and link loss measurements when paired with an optical power meter for POF testing.
Test insertion loss of multimode MT-RJ fiber optic cables and connectors, or pair with an optical power meter for link loss testing of installed cable plants.
Test insertion loss of multimode MT-RJ fiber optic cables and connectors, or pair with an optical power meter for link loss testing of installed cable plants.
Insertion Loss and Link Loss Testing: Paired with a TEMPO 555B or 558B optical power meter, the 265A serves as an ideal general purpose 1310nm laser source for measuring the insertion loss of single-mode fiber optic cables and connectors. The 265A can also be used with an optical power meter for dual wavelength link loss testing of installed cable plants. The 265A laser source is particularly useful for testing and maintaining telecommunications systems and other long wavelength single-mode fiber optic networks operating at 1310nm.
Insertion Loss and Link Loss Testing: Paired with a TEMPO 555B or 558B optical power meter, the 266A serves as an ideal general purpose 1550nm laser source for measuring the insertion loss of single-mode fiber optic cables and connectors. The 266A can also be used with an optical power meter for link loss testing of installed cable plants. The 266A laser source is particularly useful for testing and maintaining telecommunications systems and other long wavelength single-mode fiber optic networks operating at 1550nm.
The AEMC 2620 High-Sensitivity AC Leakage Current Probe measures and detects current leakage shunted to the ground due to insulation faults. Permits the operator to anticipate failures and locate failures if they have occurred without the need to shut-down equipment.
AEMC MN114 AC Current Probe Leakage Current Tester is a general purpose mini probe which offers 1mA to 10AAC, continuous cycle current range. The output signal is 100mVAC/AAC (1V at 10A). It was designed to optimize measurements on 5A signals. The output termination is a 5ft lead with safety 4mm banana plug.