Main page content
AEMC MN252 is a general purpose AC current probe with voltage output. It is designed for use with DMMs or with measuring instruments with voltage inputs. These probes permit the measurement or recording of current with instruments without current ranges. The voltage output is proportional to the current measured (through the jaws). The AEMC MN252 offers a voltage output of 10mV per Amp measured. The AEMC MN252 has jack outputs that accept 4mm banana plugs.
AEMC MN254 is a high sensitivity probe with voltage outputs (100mV/A and 10mV/A) and combine two switch-selectable ranges of 20A and 200A, thus permitting accurate measurements at low and high levels. The AEMC MN254 has jack outputs that accept 4mm banana plugs.
AEMC MN255 is a high sensitivity probe with voltage outputs (100mV/A and 10mV/A) and combine two switch-selectable ranges of 20A and 200A, thus permitting accurate measurements at low and high levels.
AEMC MN291 is a general purpose AC current probe with voltage output. It is designed for use with DMMs or with measuring instruments with voltage inputs. The AEMC MN291 AC Current Probe permits the measurement or recording of current with instruments without current ranges. The voltage output is proportional to the current measured (through the jaws). The MN291 offers a VDC output of 100mVDC per AAC and may be used with loggers or other instruments with DC voltage input.
AEMC MN306 is designed for low AC current measurements up to 10A, such as secondary of CTs or even small motors and appliances. It offers a higher voltage output of 100mV per Amp (1VAC @ 10AAC) for enhanced sensitivity at lower levels, while offering a high crest factor at full range. The MN306 has a jack output that accepts 4mm banana plugs.
AEMC MN307 is designed for low AC current measurements up to 10A, such as secondary of CTs or even small motors and appliances. It offers a higher voltage output of 100mV per Amp (1VAC @ 10AAC) for enhanced sensitivity at lower levels, while offering a high crest factor at full range.
AEMC MN312 is a high accuracy and lower phase shift AC current probe. It has a 1000:1 ratio and an output of 1mA per A in the primary (inside the jaws). The AEMC MN312 has a jack output that accepts 4mm banana plugs.
AEMC MN352 is a high accuracy and low phase shift AC current probe with voltage output. It is designed for use with DMMs or current measuring instruments with voltage inputs. The voltage output is proportional to the current measured (through the jaws).
AEMC MN353 is a high accuracy and low phase shift AC current probe with voltage output. It is designed for use with DMMs or current measuring instruments with voltage inputs. The voltage output is proportional to the current measured (through the jaws).
AEMC MN373 is a dual range current probe designed to measure low current (to 200A) with high accuracy and phase shift.
AEMC SR701 is a general purpose 1000AAC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp measured in the jaw. The AEMC SR701 has jack output terminations that accept 4mm banana plugs.
AEMC SR704 is a general purpose 1000AAC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp measured in the jaw. The AEMC SR704 has an integral 5 ft (1.5m) lead terminated by shrouded banana plugs.