Fluke 1507 Handheld CAT IV 600V Insulation Resistance Tester
5066006
QVT-2008070316263823233
Electrical
The Fluke 1507 Handheld CAT IV 600V Insulation Resistance Tester is rugged, reliable, easy to use, and compact. Capable of testing multiple test voltages making this resistance tester ideal for troubleshooting and preventative maintenance.
Features
| Chracteristics: | Fluke 1507 Handheld CAT IV 600V Insulation Resistance Tester |
| Measures insulation from 0.01M? to 10G? | |
| Test Voltage range: 1000V, 500V, 250V, 100V, 50V | |
| Automatic PI, and DAR calculation | |
| Pass/fail comparison feature | |
| Includes remote test probe for hard to reach areas | |
| Auto restriction if live sample is greater than 30V | |
| Automatic discharge of capacitive voltage | |
| Measures AC/DC voltage from 0.1V to 600V | |
| Continuity up to 200mA | |
| Measures resistance 0.01? to 20.00k? | |
| Automatic Shut-off feature | |
| Full illuminated display | |
| CAT IV 600V rating | |
| Includes: Probes and alligator clips, remote probe, and test leads |
Specifications
| Specifications: | Fluke 1507 Insulation Resistance Tester 2427890 |
| Maximum voltage applied to any terminal: | 600 V AC RMS or DC |
| Storage Temperature | -40 °C to 60 °C (-40 °F to 140 °F) |
| Operating Temperature | -20 °C to 55 °C (-4 °F to 131 °F) |
| Temperature Coefficient | 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) |
| Relative Humidity | 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) 0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) 0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) |
| Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument |
| Shock | 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) |
| Electromagnetic compatibility: | In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) |
| Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) |
| Certifications: | CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition |
| Batteries | Four AA batteries (NEDA 15A or IEC LR6) |
| Battery Life | Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. |
| Size | 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) |
| Weight | 550 g (1.2 lb) |
| IP Rating | IP40 |
| Altitude | Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V Non-operating (storage): 12,000 m |
| Over-range capability: | 110 % of range |
| AC/DC Voltage Measurement: | |
| Accuracy: | Range 600.0 V Resolution 0.1 V 50 Hz to 400 Hz ± (% of Rdg + Digits) ± (2 % + 3) |
| Input impedance | 3 MΩ (nominal), < 100 pF |
| Common mode rejection ratio (1 kΩ unbalanced) | > 60 dB at dc, 50 or 60 Hz |
| Overload Protection | 600 V RMS or DC |
| Earth bond resistance measurement: | |
| Range/Resolution | 20.00 Ω 0.01 Ω 200.0 Ω 0.1 Ω 2000 Ω 1.0 Ω 20.00 kΩ 0.01 kΩ |
| Accuracy | ± (1.5 % + 3) |
| Overload Protection | 2 V RMS or DC |
| Open Circuit Test Voltage | > 4.0 V, < 8 V |
| Short circuit current | > 200.0 mA |
| Insulation specifications: | |
| Measurement Range | 0.01 MΩ to 10 GΩ |
| Test voltage | 50 V, 100 V, 250 V, 500 V, 1000 V |
| Test Voltage Accuracy | + 20 %, - 0 % |
| Short circuit current | 1 mA nominal |
| Auto Discharge | Discharge time < 0.5 second for C = 1 °F or less |
| Live circuit indicator | Inhibit test if terminal voltage > 30 V prior to initialization of test |
| Maximum Capacitive Load | Operable with up to 1 °F load |
| Measure Accuracy: | 50 V: ±(3 % + 5) 100 V: ±(3 % + 5) 250 V: ±(1.5 % + 5) 500 V: ±(1.5 % + 5) 1000 V: ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ |