Main page content
Yellow Jacket Combustion Analyzer CA502 for Ambient CO Monitor, Manometer, and Combustion Analyzer
68601
QVT-2023091285009853131
Yellow Jacket CA502 Combustion Analyzer
The Yellow Jacket residential combustion analyzer CA502 is an essential instrument for ensuring the safety, efficiency, and proper operation of heating appliances. The three-in-one flue gas analyzer features an ambient CO and flue gas monitor, a manometer, and analyzer functionality in one compact tool. The CA502 combustion analyzer includes oxygen and carbon monoxide gas sensors, an efficiency test, and the ability to provide rapid reporting via the Yellow Jacket App.
Measured values: O2, CO, Combustion air temp, Gas pressure in the piping, pressure in the burning chamber and check of the pressure switches, using the measurement range up to 5.9 in hg (200hPa), Pressure measurement, Pressure measurement of the gas inlet line, CO environment measurement, and Draft measurement
Calculated values: Stack leaks, Combustion efficiency, CO2, NOX, Air excess, Poison index (CO/CO2 ratio)
The Yellow Jacket CA502 combustion analyzer does not include a printer. Yellow Jacket model CA502P has the same features and a Wireless Bluetooth® Printer.
Main Benefits
- 2 Gas Sensors for O2 and CO
- Draft, Pressure and Temperature Measurements
- High CO Protection
- Field-Replaceable Sensors
- CO2, Combustion Efficiency, Excess Air
- Ambient CO Monitoring
- Yellow Jacket Combustion App
- Automatic Generation of QR Code to Download
- Analyses to Share with Customers or for Records
- CO Air Free
- Built-in Dual Pressure Manometer
- Ideal for High-Efficiency Condensing Systems
- Internal Data Storage
Compact and lightweight, the Yellow Jacket CA502 analyzer with its magnetic protective holster fits comfortably in your hand, and the six simultaneous readings are read easily on the display. The CO over-limit protection provides sensor longevity, and the 7” duct probe with adjustable depth stop allows for easy installation and use at any job site.
The inline condensate trap and soot filter provide easy viewing and easy change out and cleanup at the end of a job. A replaceable filter is integrated into the suction line and can be replaced while emptying the water trap. The onboard pre-calibrated O2 sensors are easily field-replaceable, allowing for reduced downtime.
The combustion analyzer integral manometer functionality and optional manometer tube accessory allow monitoring of system and flue pressures. The integrated startup zeroing makes this analyzer a great ambient and flue gas CO detector, and the analyzer displays the PPM for CO, preventing local CO poisoning hazards. In addition, the flue gas analyzer will set fuel to the proper efficient burn. The Yellow Jacket Combustion Analyzer CA502 includes all the features needed to efficiently, effectively, and safely service heating appliances.
The Yellow Jacket Combustion App allows the HVAC technician to scan the QR code generated by the CA502 to download the data of the performed analyses and store, email, or print the report.
What is Included?
- Analyzer with Protective Magnetic Rubber Holster
- Water Trap with Filter Cartridge
- Flue Gas Probe 7” with Positioning Cone
- 5’ Dual Hose
- Rechargeable Battery and AC Charger
- Protective Hard Carrying Case
- Quick Start Guide
- Calibration Certificate
- 12-month warranty
Features
- 2 Gas Sensors for O2 and CO
- Draft, Pressure and Temperature Measurements
- High CO Protection
- Field-Replaceable Sensors
- CO2, Combustion Efficiency, Excess Air
- Ambient CO Monitoring
- Yellow Jacket YJ Combustion App
- Automatic Generation of QR Code to Download Analyses to Share with Customers or for Records
- CO Air Free
- Built-in Dual Pressure Manometer
- Ideal for High-Efficiency Condensing Systems
- Internal Data Storage
- 15 Programmed Fuels (including #2 Oil, #4 Oil, #6 Oil, Natural Gas, Propane, Wood, Biofuel and more)
- Backlit Display for Easy Viewing
- Protective Magnetic Rubber Holster for Hand Free Operation
- Long Lasting Rechargeable Battery
- holds charge for 8 hours
- Optional Wireless Bluetooth® Printer (included in CA502P P/N 68602)
- High Altitude Adjustment
- 12-Month Warranty
Specifications
| Specifications: | Yellow Jacket CA502 Combustion Analyzer | |||
| Parameter | Sensor | Range | Resolution | Accuracy |
| Oxygen (02) | Electrochemical | 0 to 25% volume | 0.01% volume | ±0.2% volume |
| CO High Immunity H2 with NOx Filter | Electrochemical | 0 .. 4000 ppm | 1 ppm | ±20 ppm 0 .. 400 ppm ±5% measured value 401 .. 4000 ppm |
| CO2 | Calculated | 0 .. 99.9% vol. | 0.1% vol. | |
| Air Temperature | TcK Sensor | -4.0 .. 248.0 °F -20.0 .. 120.0 °C | 32.18 °F 0.1 °C | ±33.8 °F ±1 °C |
| Flue Gas Temperature | TcK Sensor | -4.0 .. 1472.0 °F -20.0 .. 800.0 °C | 32.18 °F 0.1 °C | 33.8 °F (±1 °C) 32 ... 212 °F (0 .. 100 °C) ±1% Measured Value 213.8 .. 1472 °F (101 .. 800 °C) |
| Pressure (draft and differential) | Piezo Resistive | -40.1 .. +80.4 inH20 | 0.004 inH20 | ±1% Measured Value -40.1 .. -0.81 inH20 ±0.08 inH20 -0.80 .. +0.80 inH20 ±1% Measured Value +0.81.. +80.4 inH20 |
| Temperature Differential | Calculated | 31.0 .. 1472.0 °F 0 .. 800.0 °C | 0.1 °C | |
| Air Index | Calculated | 0.00 .. 9.50 | 0.1 | |
| Excess Air | Calculated | 0 .. 850% | 1% | |
| Stack Losses | Calculated | 0.0 .. 100.0% | 0.10% | |
| Efficiency | Calculated | 0.0 .. 120.0% | 0.10% | |
| General Specifications: | ||||
| Dimensions | Analyzer: 2.8 x 2.4 x 6.7 inches (Width x Depth x Height) Case: 15.7 x 11.4 x 4.7 inches (Width x Depth x Height) | |||
| Weight | ~ 0.77lbs (12.3 Oz) | |||
| Display | Graphic white LED backlit White / Black, 128 x 128 pixel | |||
| Air pressure: | Atmospheric | |||
| Humidity limit: | 20% .. 80% RH | |||
| Protection | IP42 | |||
| Connectivity: | Communication port: USB connector type B. Bluetooth® Class 1. Communication distance <328’ (100 meters) (in open field) Infrared interface: For external printer (optional) using protocol HP-IR. | |||
| Power: | Li-Ion battery pack with internal protection circuit. Average life of the battery package: 500 empty / full charge cycles. | |||
| Battery charger: | External 5Vdc 2A battery charger with female A-type USB connector + connection to the device with the serial communication cable supplied. | |||
| Charging time: | 5 hours to charge from 0% to 90% (6 hours for 100%). The device can also be charged by connecting it to the PC, the device must be turned off, the charging time depends on the output current from the PC and may be more than 12 hours. | |||
| Instrument working time: | 8 hours of non-stop operation with display brightness at 50%. | |||
| Condensing boiler efficiency: | Automatic recognition of the condensing boiler, with calculation and printout of efficiency (>100%) on the LHV (Lower Heating Value). | |||
| Environmental gases: | Measurement and separate printout of the ambient CO values. | |||
| Draft test: | By using the internal sensor connected to the port P+. | |||
| Operating temperature range: | 23°F .. 113°F (-5°C .. +45°C) | |||
| Storage temperature range: | -4°F .. 122°F (-20°C .. +50°C) | |||
| Internal data memory: | 5 complete analyses. | |||
| Suction pump: | 0.26 gal. per minute (1.0 l/min) of flue gas at 32.15 inH2O (80hPa). | |||
| Gas measurement sensors: | Up to 3 electrochemical sensors | |||
| Type of combustible: | 12 predefined by the factory. | |||
| Instrument working time: | 8 hours of non-stop operation with display brightness at 50%. | |||
| Autozero: | Settable (30 .. 600 seconds) | |||
| Self-diagnosis: | Checks all functions and internal sensors and reports any abnormal operation. | |||
| Temperature measurement: | Input for thermocouple type K with mignon connector (ASTM E 1684-96) for the temperature measurement. | |||
| Room temperature measurement: | Through the internal sensor and/or acquisition through the gas probe positioned in air. | |||
| Condensate trap: | . | |||
| Type: | Outside the instrument. | |||
| Line filter: | With replaceable filter (68612), 99% efficient with 20um particles. | |||
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Resources

Yellow Jacket CA502 Combustion Analyzer - Data Sheet

Yellow Jacket CA502 Combustion Analyzer - Quick Start Guide

Yellow Jacket CA502 Combustion Analyzer - User Manual
The 3-IN-1 Combustion Analyzer for Safe, Accurate Diagnostics.