Main page content
Wohler A 550 L Advanced Combustion Analyzer with Touch Screen Display 7754 is a robust and intuitive next generation combustion analyzer that is as easy to use as a smartphone and heavy-duty enough for the job site. Wohler A 550 L is designed with a 7" full color touch screen that is easy to navigate, displays all relevant readings, and is great for showing results to customers or supervisors in an easy to understand manner. This unique analyzer also features USB and IR communication, instant printouts and measures O2 and CO, as well differential pressure, temperature, wood moisture and more.
Features
| Characteristics: | Wohler A 550 L Advanced Combustion Analyzer with Touch Screen Display 7754 |
| 4 Year Warranty | |
| Simple to use and understand | |
| Large color touchscreen displays of to 14 measurement ad calculation values | |
| Onscreen keyboard for intuitive operation | |
| Easily accessible 4-filter technology | |
| Can run diagnostics for unit and sensors | |
| User-friendly sensor replacement | |
| More than 12 hours use with Lithium Ion rechargeable battery | |
| Flexible and durable probe assembly | |
| Probe is insertion type for wide-ranging applications | |
| First flue gas analyzer to include wood moisture meter | |
| Stores up to 1,000 measurement records | |
| USB, or infrared data transfer | |
| Approvals: TÜV By RgG 297, EN 50379 - 2, VDI 4206, EN 50379 - 1 for CO | |
| Wohler A 550 L includes: | hose 5.6 ft and gas probe 0.9 ft, USB charger with micro USB cable, Li-Ion battery, water stop filter, coarse filter, 25 wadding filters, Wohler TD 100 thermal fast printer, case |
Specifications
| Specifications: | Wohler A 550 L Advanced Combustion Analyzer with Touch Screen Display 7754 |
| Oxygen concentration (O2) in flue gas | |
| Display | Volume % referenced to dry flue gas |
| Measurement principle | Electrochemical sensor |
| Range | 0.0 – 21.0 vol. % |
| Accuracy | ±0.3 Vol. % |
| Carbon monoxide (CO) in flue gas | |
| Display | Volume ppm referenced to dry flue gas |
| Measurement principle | Electrochemical sensor |
| Range | 0 – 35,000 vol. ppm; resolution 1 vol. ppm |
| Accuracy | ±100 ppm (< 1,000 ppm), otherwise 10 % of reading (with H2 < 5% of reading) |
| Chimney draft / differential pressure (PD) | |
| Display | inWC |
| Measurement principle | Semi-conductor diaphragm |
| Range | 0.00 to ± 44.16 inWC; resolution 0.004 inWC |
| Accuracy | 0.008 inWC (< 0.16 inWC), otherwise 5 % of reading |
| Flue gas temperature (TS) | |
| Display | °F |
| Measurement principle | Thermocouple (NiCr-Ni) (NiCr-Ni) |
| Range | -4 °F to 1,472 °F; resolution 32.18 °F |
| Accuracy | 32 – 271.4 °F: ±35.6 °F 271.4 – 1,472 °F: ±1.5 % of reading |
| Combustion air temperature (TA) | |
| Display | °F |
| Measurement principle | Thermocouple (NiCr-Ni) |
| Range | -4 °F to 212 °F; resolution 32.2 °F |
| Accuracy | ±33.8 °F |
| Wood moisture | |
| Display | Mass of water referenced to dry fuel mass |
| Measurement principle | Electrical resistance measurement |
| Range | 10.0 – 40.0 %; resolution 0.1 % |
| Accuracy | ±40 % of reading tested to VDI 4206 Part 4 |
| General | |
| Power supply | Lithium-Ion, rechargeable battery 3.7 V, 5800 mAh, charges via USB |
| Battery operating time | Approx. 12 h (depends on operating status and display illumination) |
| Storage temperature | -4 °F to +122 °F |
| Operating temperature | +41 – 104 °F to maintain stated accuracy |
| Weight | 2.75 lbs |
| Dimensions | 8.7" x 6.3" x 2.2" (without probe) |
| Length of cable-hose | 67" |