Main page content
Viasensor G100-10L Handheld CO2 0-20% Incubator Analyzer CO2 plus O2
G100-10L
QVT-2010122910105011967
Viasensor G100-10L Oxygen and Carbon Dioxide Incubator Analyzer
Viasensor G100-10L CO2 0-20% Handheld Incubator Analyzer with O2 (0-100%) is designed to monitor CO2 and O2 levels for verifying incubators used in the research, IVF, pharmaceutical and medical industries. The monitoring of CO2, O2 and atmospheric conditions of incubators is vital to these industries because it has a large impact on the growth of embryos and cell cultures in the laboratory.
The Viasensor G100-10L Incubator Analyzer is equipped with an IR CO2 sensor and electrochemical O2 sensor to increase accuracy and reduce the response time of readings in comparison to traditional chemical methods. This handheld unit has a large easy to read LCD display with an LED backlight when working in darker conditions. The G100-10L includes a built-in gas dryer tube that removes moisture and an internal pump that typically operates at a flowrate of 100 cc/min. The unit is equipped with ports for optional dual temperature probes (sold separately). If a relative humidity reading is required, please see the Viasensor G100-11L which has a built-in RH port and a 15mm dia RH probe.
The Viasensor G100-10L comes with a 12 month manufacturer warranty. Made in the UK. Monitors CO2 from 0-20% Monitors O2 from 0-100% RH Port option available as G100-01L (CO2 only) and G100-11L (CO2 + O2) Dual Temperature Probe Ports (Temperature probes sold separately) Owners manual, battery charger, and sample tube kit included.
The Viasensor is ISO 9001 Certified Company.
Features
| Characteristics: | Viasensor G100-10L CO2 0-20% Handheld Incubator Analyzer with O2 (0-100%) |
| Incubator analyser package 0-20 percent CO2 + 100 percent O2 with internal pump | |
| Improved accuracy on CO2 readings | |
| Quick verification of CO2 incubator levels | |
| Time saving with dual temperature probes | |
| Large data storage and user friendly software and download | |
| Easy to read large well lit display | |
| Built in gas moisture removal | |
| Includes: | Battery charger, sample tube/filters and operating manual |
Specifications
| Specifications | Viasensor G100-10L CO2 (0-20%) Incubator Analyzer with O2 (0-100%) | |
| Gas Ranges | ||
| Gases Measured | CO2 | By custom dual wavelength infra-red with reference channel |
| O2 | By Internal Electrochemical Cell | |
| Oxygen Cell Lifetime | Approximately 3 years in air | |
| Range | CO2 | 0-20% |
| O2 | 0-100% | |
| Measurement Accuracy | Gas | |
| CO2 | Accuracy: ± (1% of range + 2% of reading) at reference conditions1 | |
| Temperature dependence: ± 0.2% reading (typical at 5% CO2) | ||
| Pressure dependence: ± 0.02% of reading / hPa (typical at 5% CO2) | ||
| O2 | ± 1.0% Full Scale @ constant temperature and pressure | |
| ± 2.0% Full Scale over operating temperature range | ||
| Response time T90 | CO2 | = 20 seconds |
| O2 | = 60 seconds | |
| 1 Conditions during factory calibration, typically 25 °C, 980 mBar | ||
| Environmental Conditions | ||
| Operating Temperature | 41 °F to 104 °F; 5 °C to 40 °C | |
| Relavtive Humidity | 0 - 95% non condensing | |
| Barometric Pressure | ± 201 "H20 from calibration pressure, (± 500mbar) | |
| Pump | ||
| Flow | 100 cc/min typically | |
| Power Supply | ||
| Battery Type | Li Ion | |
| Battery Life | 10 Hours (8 hours with pump) | |
| Battery Lifetime | > 300 Cylces | |
| Battery Charger | 5v DC external power supply and internal charging circuit | |
| Charge Time | 3 Hours | |
| Alternative Power | USB Connector | |
| DC Power Supply | ||
| Physical | ||
| Weight | 1.1 lbs (495 grams) | |
| Dimensions | 6 x 4 x 2 3/16 inches (165 x 100 x 55mm) | |
| Case Material | ABS / Polypropylene with Silicon Rubber Inserts | |
| Keys | 17 Resin capped Silicon Rubber Keys | |
| Display | Liquid Crystal Display, 128 x 64 pixel | |
| With RGB LED Backlight | ||
| Gas Sample Filters | Built-in gas dryer tube to remove moisture | |
| User replaceable PTFE water trap filter | ||
| Facilities | ||
| Temperature (Optional) | x 2 using optional probes, range 32 °F to 122 °F (0°C to +50.0 °C) | |
| Temperature accuracy, typical | ±0.2 °C from 32 to 44 °C, ±0.5 °C | |
| Barometric pressure | 800-1,200 mbar | |
| RH measurement (Optional) | RH probe 0-100% RH non condensing | |
| RH accuracy | ±1.5% RH across the range | |
| Visual and audible alarm | User selectable CO2 alarm levels | |
| Communications | USB type B mini-connect or, HID device class | |
| Data Storage | 1,000 reading sets + 270 events | |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.