UniSource DM-1140B Digital Bench Multimeter with Manual Ranging
DM-1140B
QVT-2013032521347890258
UniSource DM-1140B 4 1/2 is a manual ranging dmm that is made for benches, it has a 3/s sampling rate and overload protection. This meter also take TRMS readings, and has a LCD screen with backlight.
Features
| Chracteristics: | UniSource DM-1140B Digital Bench Multimeter with Manual Ranging |
| Manual Ranging | |
| 3x/s sampling rate with overload protection | |
| Basic DCV, ACV, DCA, ACA, &Omega, CAP, Hz, hFE, Diode and Continuity measuring functions. | |
| Voltage test range up to 1000V Direct Current or peak to peak value Alternating Current, resolution up to 10uV. | |
| Current test range up to 20A, auto polarity shift, and data hold. | |
| Alternating Current measuring with TRMS, measuring broadband and Alternating Current/Direct Current function, accurate measurements of virtual value of Alternating Current by any waveform. |
Specifications
| Specifications: | UniSource DM-1140B 4 1/2 Manual Range Digital Bench Multimeter | ||||
| Function | Range | Resolution | Accuracy | Remarks | |
| DCV | 200mV | 10uV | ±(0.05%reading+3) | Input impedance: 10MΩ for all ranges; Overload protection: 200mV range: 250VDC or AC peak value. Other range: 1000V DC or AC peak value. | |
| V | 100uV | ||||
| 20V | 1mV | ||||
| 200V | 10mV | ||||
| 1000V | 100mV | ±(0.1%reading+5) | |||
| ACV(T-RMS) | 200mV | 10uV | ±(0.8%reading+80) | 50Hz–50kHz | The input value for accuracy guarantee should be larger than 10% of full range. Input impedance: 2MΩ for all ranges. Overload protection:200mV range: 250V DC or AC peak value, other range: 1000V DC or AC peak value. |
| 2V | 100uV | 50Hz–20kHz | |||
| 20V | 1mV | ||||
| 200V | 10mV | 50Hz–5kHz | |||
| 750V | 100mV | ±(1.0%reading+50) / 50Hz–400Hz | |||
| DCA | 20mA | 1uA | ±(0.35%reading+10) | Max. input voltage drop: 200mV Max. input current: 20A (within 10s) Overload protection: 2A/250V fuse (13A/250V fuse) | |
| 200mA | 10uA | ||||
| 2A | 100uA | ±(0.8%reading+10) | |||
| 20A | 1mA | ||||
| ACA(T-RMS) | 200mA | 10uA | ±(0.8%reading+80) | Max. input voltage drop: 200mV Max. input current: 20A (within 10s) Overload protection: 2A/250V fuse (13A/250V fuse) | |
| 2A | 100uA | ±(1.0%reading+50) | |||
| 20A | 1mA | ||||
| Resistance | 200Ω | 0.01Ω | ±(0.1%reading+20) | Open circuit voltage: less than 3V Over load protection: 250V DC or AC peak value; NOTE: At range 200 Ω, short-circuit the test leads to measure the wire resistance and then subtracts it from the real measurement. | |
| 2kΩ | 0.1Ω | ±(0.1%reading+5) | |||
| 20kΩ | 1Ω | ±(0.5%reading+5) | |||
| 200kΩ | 10Ω | ||||
| 2MΩ | 100Ω | ||||
| 20MΩ | 1kΩ | ||||
| Frequency | 20kHz | 1Hz | ±(1.0%reading+20) | Input sensitivity: 500mV rms Overload protection: 250V DC or AC peak value (within 15s) | |
| 200kHz | 10Hz | ||||
| Capacitance | 20nF | 1pF | ±(3.5%+20) | Measuring frequency: approx. 400Hz Measuring voltage: approx. 40mV, Overload protection: 36V DC or AC peak value | |
| 2uF | 100pF | ||||
| 200uF | 10nF | ±(5%+30) | |||
| General | |||||
| Power | AC 220V/110V, 50Hz/60Hz | ||||
| Size | 245×220×98mm | ||||
| Net weight | 1.4kg | ||||
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.