Main page content
UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R measures up to 600V DC, 750V AC, 600A AC, DC microamps up to 2000µA, and resistance measurements up to 60M?. The UEi DL479 features non-contact voltage detection, true RMS measurements, diode testing, low battery indication, a built-in worklight, backlight, capacitance testing, temperature measurements via type k thermocouple, a convenient magnetic mount, data hold, and more.
Features
| Characteristics: | UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R |
| Accurate measurements via True RMS | |
| AC current measurements up to 600A | |
| Voltage measurements: Up to 750V AC and 600V DC | |
| Measures up to 60M? resistance | |
| Measures up to 2000µA DC microamps | |
| Diode testing functionality | |
| Non-contact voltage (NCV) detection feature | |
| Continuity test with audible cue | |
| 6000 count display | |
| Freeze readings with data hold | |
| Manual ranging option | |
| Integrated worklight for dark areas | |
| Audible cues for voltage | |
| Capacitance testing up to 2000µF | |
| Temperature testing via type K thermocouple up to 14° to 752°F (-10° to 400°C) | |
| Frequency/duty cycle testing | |
| MIN/MAX feature | |
| Backlit LCD display | |
| Convenient magnetic mount for hands free use | |
| Auto shut-off to save battery life | |
| Low battery indication | |
| Over molded grip | |
| Integrated test lead storage | |
| Automatic calibration | |
| Ideal for diode malfunctions/unbroken paths, quick check of live wires, flame safe guard, circuit continuity or specified resistance, control voltage or system board voltage checks, motor or line current, and more | |
| 2 year limited warranty | |
| Includes test leads with alligator clips, thermocouple temperature probe, zippered pouch, 2 AAA batteries, and manual |
Specifications
| Specifications: | UEI DL479 TRMS Clamp Meter 600A AC for HVAC | ||
| AC Amps - Jaw Input | |||
| Range | Resolution | Accuracy | Overload Protection |
| 60A | 0.01A | ±(2.0% +8 dgts) | 600V RMS |
| 600A | 0.1A | ||
| True RMS Frequency range: Sine 50Hz to 400Hz Frequency width: 60Hz to 400Hz: 5% to 95% Frequency width: 400Hz to 4kHz: 15% to 85% | |||
| AC Volts (45Hz to 400Hz) | |||
| Range | Resolution | Accuracy | Overload Protection |
| 600mV | 0.1mV | ±(1.0% +3 dgts) | 1000V RMS |
| 6V | 1mV | ||
| 60V | 10mV | ||
| 600V | 100mV | ||
| 750V | 1.0V | ||
| True RMS Frequency range: Sine 50Hz to 400Hz, Sine 50Hz to 400Hz Bandwidth: Sine = 0.5% error at 1.5kHz (max) Bandwidth: Square = 0.5% error at 0.1kHz (max) Bandwidth: Triangle = 0.5% error at 1.2kHz (max) | |||
| DC Volts | |||
| Range | Resolution | Accuracy | Overload Protection |
| 600mV | 0.1mV | ±(0.5% +4 dgts) | 1000V RMS |
| 6V | 1mV | ||
| 60V | 10mV | ||
| 600V | 100mV | ||
| DC Low Amps | |||
| Range | Resolution | Accuracy | Overload Protection |
| 600µA | 0.1µA | ±(1.2% +3 dgts) | 2000µA/600V RMS |
| 2000µA | 1µA | ||
| Resistance | |||
| Range | Resolution | Accuracy | Overload Protection |
| 600O | 0.1O | ±(0.8% +3 dgts) | 600V RMS |
| 6kO | 1O | ||
| 60kO | 10O | ||
| 600kO | 100O | ||
| 6MO | 0.001MO | ||
| 60MO | 0.01MO | ±(1.2% +3 dgts) | |
| Frequency | |||
| Range | Resolution | Accuracy | Overload Protection |
| 99.99Hz | 0.01Hz | ±(0.1% per+3 dgts) | 600V RMS |
| 999.9Hz | 0.1Hz | ||
| 9.999kHz | 0.001kHz | ||
| Duty Cycle | |||
| Range | Resolution | Accuracy | Overload Protection |
| 0.5% to 95% 60Hz to 400Hz | 0.1% | ±(0.2% per kHz +2.0% +2 dgts) | 600V RMS |
| 15% to 85% 400Hz to 2kHz | |||
| Diode Test | |||
| Range | Open Circuit | Test Current | Overload Protection |
| 4.0V | <3.0V DC | 1.30mA | 600V RMS |
| Capacitance | |||
| Range | Resolution | Accuracy | Overload Protection |
| 60nF | 0.01nF | ±(3.0% +5 dgts) | 600V RMS |
| 600nF | 0.1nF | ||
| 6.000µF | 0.001µF | ||
| 60.00µF | 0.01µF | ||
| 600.0µF | 0.1µF | ||
| 2000µF | 1µF | ||
| Continuity | |||
| Open Circuit | Response Time | Overload Protection | |
| <1.0V | <50ms | 600V RMS | |
| Temperature | |||
| Range | Resolution | Accuracy | Overload Protection |
| 14° to 752°F | 0.1°F | ±(1.5% +3.6°F) | 600V RMS |
| -10° to 400°C | 0.1°C | ±(1.5% +2.0°C) | |
| Stated accuracy does not account for themocople accuaracy Sensitivity >2Vpp RMS | |||
| Non-Contact Voltage | |||
| On Voltage | |||
| Approx. 25V AC | |||
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Resources
Data Sheets

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Data Sheet.pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Data Sheet (Français).pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Data Sheet (Español).pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Sell Sheet.pdf
Manuals

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Manual.pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Manual (Français).pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Manual (Español).pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Data Sheet.pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Data Sheet (Français).pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Data Sheet (Español).pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Sell Sheet.pdf
Manuals

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Manual.pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Manual (Français).pdf

UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Manual (Español).pdf
DL479 Features and Benefits