Main page content
TPI 717R Combustion Flue Gas Analyzer with Maintenance and Appliance Installation Features
717R
QVT-2015111021924039804
TPI 717R Combustion Flue Gas Analyzer with Maintenance and Appliance Installation Features measures flue temperature, CO, and O2 as well as the ability to calculate efficiency, excess air, CO2 & CO/CO2 ratio. The TPI 717R features a 10,000 ppm CO sensor with quick recovery time, an in-line water trap that protects the sensor from water damage, a pump filter that helps prevent the pump from becoming clogged with dirt/dust debris, self-diagnostic tests, and more. The TPI 717R is set apart from most combustion analyzers with extra features such as its built-in differential manometer and differential thermometer. *Rechargeable Battery Model
Features
| Characteristics: | TPI 717R Combustion Flue Gas Analyzer with Maintenance and Appliance Installation Features |
| Calculates efficiency, excess air, CO2 & (CO/CO2) ratio and measures CO, O2, and flue temperature | |
| 10,000 ppm CO sensor with quick recovery time and long-lifespan | |
| Integrated differential manometer: +/- 150 mBar (0.01 mBar resolution) great for burner pressure testing or tightness testing | |
| Differential temperature calculations via dual input k-type thermocouples - ideal for measuring and recording flow and return temperatures | |
| Magnetic backing for hands free use | |
| Water trap bowl filter protects sensors from being damage by water | |
| Mini pump filter protects the pump from dirt/dust clogs | |
| Compatible with multiple fuel types | |
| Includes handy soft carrying case | |
| On-board diagnostic software to determine unit integrity | |
| Works with optional IR Printer | |
| NiMH Rechargeable Battery (> 6 hour run-time) | |
| 3 year unit guarantee; 2 year sensor guarantee | |
| Can analyze ambient CO build up levels in a room | |
| Test pressure readings | |
| Includes: TPI 717R, rubber boot (A765), soft carrying case (A768), flue sampling probe (A770), in-line filter assembly installed on flue probe (A796), temperature probe (GK11M), mini pump protection filter assembly and spare filter (A763), exhaust spigot (removable)(A764), and Instruction manual | |
| Options/Accessories available: Infrared printer (A740), spare in line filter (A762F is a package of 5 filters), field replaceable smart CO sensor (A7605), field replaceable smart O2 sensor (A7615) |
Specifications
| Specifications: | TPI 717R Combustion Flue Gas Analyzer with Appliance Installation and Maintenance Features | ||
| Instrument | |||
| Operating Temperature Range | 14°F to +122°F (-10°C to +50°C) | ||
| Battery/Battery Life | Rechargeable Ni-MH / > 6 Hours | ||
| Charger Input Voltage | 115V or 230V : 50/60 Hz AC | ||
| Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse | ||
| Pressure Ranges | mbar, kPa & inH2O | ||
| Display | Backlit Graphic LCD | ||
| Data Storage | 50 sets of readings, multiple pages | ||
| Time and Date | 24 Hour Real Time Clock | ||
| Dimensions | 200mm x 90mm x 60mm | ||
| Weight | 500g | ||
| Casing | Rubber Boot as Standard | ||
| Switch Off | Failsafe | ||
| Exhaust | Safety Spigot | ||
| Conforms to | EN50379, BS7967 | ||
| Flue Temperature Probe | |||
| Construction | Pistol Grip with Stainless Steel Shaft | ||
| Hose Length | 2500mm | ||
| Insertion Length | 200mm | ||
| "K" Type Thermocouple Accuracy | +/- 0.3%, +/- 1°C | ||
| Maximum Temperature | 800°C | ||
| Gases | Range | Resolution | Accuracy |
| Oxygen | 0-25% | 0.1% | +/- 0.3% |
| Carbon Monoxide | 0-10,000 ppm | 1 ppm | <20ppm +/- 3 ppm >100ppm +/- 5% |
| Carbon Dioxide (Calculated) | 0-25% | 0.1% | +/- 0.3% |
| Combustion Efficiency | 0-100% | 0.1% | - |
| Pressure Measurement | |||
| Selectable Ranges | mbar, kPa and inH2O | ||
| Range | - 150 mbar to + 150 mbar | ||
| Resolution | 0.01 mbar & 0.1 mbar | ||
| Accuracy | +/- 0.5% fsd | ||
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Resources
Video TPI 717R Combustion Flue Gas Analyzer with Maintenance and Appliance Installation Features https://youtu.be/WlasY63BxWw