Main page content
TPI 556C1 Vane CFM Thermo Anemometer measure air velocity, air flow and temperature, Five units of measure for air velocity: (m/s, km/hr, mile/hr, knots, ft/min), Two units of measure for air flow: (cfm, cmm), Send real time and logged data to a PC via optional A500 interface cable, Four digit dual line display simultaneously shows air flow and temperature, Data record displays minimum, maximum and average readings, Data log up to 1000 readings in 1 second to 999 second interv.
Features
| Measure air velocity, air flow, and temperature | |
| Five units of air velocity (m/s, km/hr, mile/hr, knots, ft/min) | |
| Two units of air flow (cfm, cmm) | |
| Send real time and logged data to a PC via optional A500 interface | |
| Four digit dual line display simultaneously shows air flow and temperature | |
| Data record displays minimum, maximum, and average readings | |
| Data log up to 1000 readings in 1 sec to 999 sec intervals |
Specifications
| Air Velocity | (Low friction ball conventional twist wheel) 80 to 5916 ft/min 0.4 to 30 m/s |
| Units of Measure | m/s, km/s, ft/min, mile/hr, knotts |
| Air Velocity Accuracy | ±(1 percent of rdg + 3 digits) |
| Temperature | (Precision thermistor) -5 degrees F to 175 degrees F -20 degrees C to 80 degrees C |
| Temperature Accuracy | ±(1 percent of rdg + 1 degrees F + 3 digits) |
| Units of Measure | degrees C / degrees F |
| CFM Calculation | Automatic (Input duct size through keypad) |
| RS-232 Output | Yes |
| Min/Max Record | Yes |
| Operating Temperature (Base Unit) | 32 degrees F to 122 degrees F |
| Operating Humidity (Base Unit) | 80 percent non-condensing |
| Battery Type | 9V alkaline batteries |
| Battery Life | 30 hours typical |
| Dimension | W x L x H 2.9 inch x 5.7 inch x 1.1 inch |
| Weight | 0.3lb |
| Measurement Ranges | Air Velocity: 80ft/min. to 5916ft./min |
| Air Flow: | 0cfm to 9999cfm |
| Display: | 4 Digit Dual line LCD |
| Resolution (max): | 1 ft/min (0.1 m/s) / 0.1 degrees F/ degrees C |
| Accuracy: | +(1 percent of reading + 3 digits) |
| Functions: | User entry of duct area for air flow measurement, Data Hold, Unit Selection, Data Logging, Auto power Off, Min / Max Record |
| Air flow: | cfm, cmm |
| Data logging: | 1000 Data, 1sec to 999sec interval |
| Record: | Display Minimum / Maximum / Average readings |
| Communication: | Stream logged and realtime data to PC via optional A500 interface cable and Microsoft Hyper Terminal or similar program |
| Auto Power Off: | 10 minutes |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.