Main page content
Testo 570 RSA Refrigeration System Analyzer with Data Storage
0563 5703
QVT-2012062634297529318
Testo 570 Refrigeration System Analyzer with data storage and 4-way valve block, is ideal for installing and troubleshooting all types of refrigeration, AC systems, and heat pumps. Calculate superheat and sub cooling simultaneously, in real time, every day with two external temperature probes that come with the 570. The Testo 570 saves the user time during heat pump mode by automatically switching over the high and low side pressure and temperature without the hoses having to change. The Testo 570 can be programmed and left to automatically collect and store data for up to a period of 72 hours! This extra time and collected data allows for the technician to accurately diagnose system errors that could have easily been missed in a manual process. For complete data management the Testp 570 uses the exclusive Testo RSA software, easyKool. This provides onsite reports to customers as well as printing and displaying measuring results. The Testo 570 comes with: the refrigeration system analyzer, (0613 5505) 2 clamp probes (NTC), (0449 0047) USB cable, and (0516 5700) hard carrying case.
Features
| Features: | Testo 570 Refrigeration System Analyzer with Data Storage |
| Four-way valve block with four connections, four hose parkers and sight glass | |
| Simultaneous superheating and subcooling calculations in real-time using two external temperature probes | |
| Integrated vacuum measurement to support system evacuation | |
| Temperature-compensated leak testing | |
| Heat pump mode | |
| Three temperature probe connections | |
| Optional EasyKool software for data management |
|
| 40 refrigerant profiles stored in instrument | |
| Record up to 72 hours of measurement values | |
| Includes: | Refrigeration system analyzer, (0613 5505) 2 clamp probes (NTC), (0449 0047) USB cable, and (0516 5700) hard carrying case. |
Specifications
| Specifications: | Testo 570 Refrigeration System Analyzer with Data Storage |
| Pressure | psi /kPa / MPa/ bar |
| Temperature | °F / °C / K |
| Vacuum | psi / hPa / mbar / Torr / in H2O / Micron / in Hg / Pa / bar |
| Sensors | |
| Pressure | 2 x pressure sensors |
| Temperature | 3 x NTC |
| Interfaces | 3 x Mini-DIN, 1x Mini USB, 1x IR |
| Measuring Ranges | |
| Pressure HP/LP (rel) | 0 to 725 psi; -100 to 5000 kPa; -0.1 to 5 MPa; -1 to 50 bar |
| Temperature | -58° to 302°F |
| Vacuum (rel) | -14.5 to 0 psi |
| Overload pressure | 754 psi; 52 bar |
| Resolution | |
| Pressure | 0.1 psi; 1 kPa; 0.001 MPa; 0.01 bar |
| Temperature | 0.1 °F; 0.1 °C |
| Vacuum | 1 hPa / 0.5 Torr/ 0.5 inH2O/ 100 Pa / 500 Micron / 1 mbar |
| Accuracy (at 72°F) | |
| Pressure | ± 0.5 %fs |
| Temperature | ± 1.0 °F |
| Vacuum | 500 Micron / 1 hPa/ 0.5 Torr / 0.5 inH2O/ 100 Pa / 1 mbar |
| No. of refrigerants | 40 |
| Selectable refrigerants | Check spec sheet |
| Measurable media | CFC, HFC, N, H2O, CO2 |
| Operating temperature | -4° to 122°F |
| Storage temperature | -4° to 140°F |
| Humidity application range | 10 to 90% RH |
| Other | |
| Material | IP Protection class: 42 |
| Power supply | 4 x AA |
| Battery life | >40 hrs. (without backlight), 72°F |
| Display | Illuminated LCD display |
| Warranty (years): | 2 |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.