Main page content
Seitron Novo 1 Combustion Analyzer - 2 Gas
The Seitron Novo 1 combustion analyzer with O2 and CO Sensors is designed to provide accurate, reliable analysis for HVAC technicians. The Seitron Novo Combustion Analyzer now features the new-Pro Analysis Mode, which displays in real-time the measurement data on a combustion guide and stoichiometric chart to make analysis even easier. Other features of the Novo 1 gas analyzer include a large 7” intuitive touchscreen with easy navigation, a 4-year O2 sensor, a single probe with an easy plug-n-play connection for temperature, draft, and flue gas measurements, a dual-range (low/high) sensor technology, and an innovated water trap design. The Seitron Novo 1 combustion analyzer does not include a printer.
Need a printer? Check out the Seitron Novo 1-P Combustion Analyzer same features but with a built-in printer.
Main Benefits
- NEW - Pro Analysis Mode (see the box below to discover how it works!)
- 7’’ touch display for easy menu navigation
- Dedicated probe with one simple connection
- Integrated water trap with LED backlight for easy maintenance
- Simultaneous measurement of gas and combustion results
- New dual range sensor technology
- Built-in Manometer for Draft, Gas Pressure, & Differential Pressure
- CO Protection Dilution Pump
- Field replaceable, pre-calibrated sensors
- 15 preprogrammed fuels
NEW Pro Analysis Mode
How does it work?
- Select Fuel Type & Equipment Type (80% Boiler, 90% furnace, water heater, etc)
- Watch & Stabilize your Combustion readings in the GREEN Zone for optimal combustion
- View Stoichiometric Chart / Graph
- Print or Email the results

Novo 1 Combustion Analyzer 2-Gas (O2, CO/H2)
The Seitron Novo 1 flue gas analyzer includes O2, CO/H2 sensors. The Novo combustion analyzer is upgradeable at the factory to add a 3rd gas sensor. The new generation of long-life gas sensors enhances the reliability and accuracy of measurements. In addition, the Novo analyzer includes a dilution pump which helps protect the CO sensor from high gas concentrations that might otherwise damage the sensor.

Display and Probe
The 7’’ display grants maximum visibility of all information along with quick and smooth browsing experience.
One source of major improvement of our analyzer is the new flue gas sampling probe connection. Instead of three separate connections for temperature, draft and flue gases, it has been redesigned to just one simple connection. The new connection allows the user to connect the probe without looking with an easy plug-n-play design.

Water Trap
The water trap design has been completely innovated to guarantee maximum performance and easy maintenance. A large inspection window with backlit LED allows the user to quickly and very easily check the water level and filter at any time.

Combustion parameters and gas pressures
Thanks to the possibility of measuring combustion parameters and gas pressures at the same time, Novo drastically reduces service time and limits the need to use different devices.

New Dual Range Sensor Technology
How many times have you had the doubt, should I use a high or low range sensor? Stop asking yourself, starting from today you will have just one sensor for both ranges. NOVO detects gas concentrations and automatically adjusts the scale, ensuring the sensor life and the measurement resolution.

Built-in Printer
For additional convenience, the Seitron Novo 3-P flue gas analyzer includes a integrated thermal printer that prints on non-fading paper, eliminating having to connect wirelessly to a Bluetooth printer as well as carrying additional equipment to a worksite to print your combustion readings.

What’s Included
- (1) Seitron Novo 1 combustion analyzer
- (1) Gas probe with 12" interchangeable tip
- (1) 6 ft Single Connection Hose
- (1) Integrated water trap
- (1) Manometer Hoses
- (1) Outdoor Combustion Air Temp Probe
- (1) AC Power Adapter & Cable
- (1) Hard plastic kit case
- (1) Quick Guide
- (1) Calibration Certificate
- Warranty - 2 years on the unit and sensors, 4 years on the O2 sensor
Features
- Measure Oxygen (O2), Carbon Monoxide (CO), and Carbon Dioxide (CO2)
- ALL Gas Sensors are Pre-Calibrated and Field Replaceable
- New 7" Touch Full Color Graphic Display Screen for Easy Menu Navigation
- New Dual Range (Low/High) Sensor Technology
- Automatic autozero (with gas sampling probe inserted in the chimney)
- Self-diagnosis with verification of the functions and status of the sensors
- New Dedicated Probe with One Simple Connection Easy Plug-n-Play Design
- New Gas probe with 12" (300 mm) Interchangeable Tip
- New Integrated Water Trap with LED Backlight for Easy Maintenance
- New 100 MB for Complete Analysis Memory
- Memory Capable of Storing up to 2,000 Full Analysis
- Dilution Pump For CO Auto-Range Measurements Up To 50,000 ppm
- Simultaneous Gas Pressure + Combustion Measurements
- 15 Preprogrammed Fuels Including Natural Gas, Oil, Propane and Biofuels
- Efficiency, Excess Air, and CO2 Calculations
- Differential Flue Gas and Ambient Air Temperatures
- Incoming Air Temperature and Ambient Air Temperature
- Rechargeable Lithium Ion Battery Pack
- Language selectable by User
- Altitude Adjustment
- Integrated magnets
- New Seitron Smart Analysis App for iOS and Android
Specifications
| Specifications: | Seitron Novo Combustion Analyzer | |||
| Parameter | Sensor | Range | Resolution | Accuracy |
| Oxygen (02) Long Life Sensor | Electrochemical | 0 to 25% volume | 0.1% volume | ±0.2% volume |
| Carbon Monoxide (CO) Compensated H2 With Over Range Protection WITH Built-in NOx Filter | Electrochemical | 0 to 500 ppm 501 to 8,000 ppm | 0.1 ppm 1 ppm | ±2 ppm (0 to 40.0ppm) ±5% measured value (40.1 to 500 ppm) ±10% measured value (501 to 8000 ppm) |
| Carbon Monoxide (CO) DILUTED | Electrochemical | 0.8% - 5.00% | 0.01% | ±10% rdg |
| Carbon Dioxide (CO2) | Calculated | 0 to 99.9% | 0.1% | |
| Temperature Gas | Type K Thermocouple | -4 to 2280°F (-20°C to 1250°C) | ±0.1°F | ±2°F (1.1°C) between -4.0°F to 212.0°F (-20°C to 100°C) ±1% Measured Value between 212.2°F to 2282.0°F (100°C to 1250°C) |
| Differential Temperature | Calculated | -4 to 2280°F (-20°C to 1250°C) | ±0.1°F | ±2°F (1.1°C) between -4.0°F to 212.0°F (-20°C to 100°C) ±1% Measured Value between 212.2°F to 2282.0°F (100°C to 1250°C) |
| Pressure/Draft | Piezo Resistive | -250.0 to 250 Pa | 0.1 Pa | ±0.5 Pa Measured Value -10.0 to +10.0 Pa ±2 Pa Measured Value +10.1 to +250 Pa ±2 Pa measured value -10.1 to -250.0 Pa |
| Combustion Efficiency | Calculated | 0 to 100% | 0.1% | |
| Excess Air | Calculated | 0 to 850% | 1% | |
| General Specifications: | ||||
| Display | Color TFT 7" touch screen (85x155mm) with CTP with backlight | |||
| Optional Integrated Printer | Thermal integrated with easy loading paper and sensor for the presence of paper | |||
| Printout Heading | 4 lines x 24 characters, customizable by the user | |||
| Printer Power Supply | From the analyzer battery pack | |||
| Internal Data Storage | 100 MB for complete analysis memory | |||
| Data Communication Port and/or Power Supply | USB with connector TYPE C | |||
| Bluetooth Communication | Class 1 / Communication range: <100 meters (open field) | |||
| Power Supply | Rechargeable battery, Li-Ion battery pack with internal protection circuit | |||
| Battery Life | 8 hours of continuous operation (printing excluded) | |||
| Charging Time | 6 hours to recharge from 0% to 90% | |||
| Operating Temperature | 23 to 113°F (-5°C to +45°C) | |||
| Storage Temperature | -4 to +122°F (-20°C to +50°C) | |||
| Operating Humidity Range | 20% to 80% RH | |||
| Air Pressure | Atmospheric | |||
| Probe Connector | 6' (1.8 m) Simple One Probe Connection for temperature, draft and flue gases | |||
| Probe Dimensions | 12 inch (300mm) interchangeable tip 1112°F (600°C) | |||
| Outer Dimensions Analyzer | 10.6 x 3.6 x 2.7in (270 x 93 x 68mm) (H x W x D) | |||
| Weight | Approx. 2 lbs (1 kg) | |||
| Kit Dimensions | 5 x 18 x 13in (125 x 465 x 335mm) (H x W x D) | |||
| Weight | Approx. 11 lbs (5 kg) | |||
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Resources

Seitron Novo Combustion Analyzer - Brochure

Seitron Novo Combustion Analyzer - User Manual

Seitron Novo Combustion Analyzer - Quick Guide
Novo - Seitron Combustion Analyzer
Combustion Test With Seitron Novo Combustion Analyzer
Novo Combustion Analyzer: Introducing PRO MODE Analysis