Fluke I310S AC/DC Current Clamp. The i310s current probe is based on Hall Effect technology for use in measurement of both DC and AC current. Fluke i310s may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement. Mfg part Fluke 2840309. Fluke parts and accessories.
Features
| Current Ranges: | 30 A and 300 A AC RMS or ±45 A and 450 A DC |
| Measuring Ranges: | ±45 A and 450 A |
| Output Sensitivity: | 10 mV/A (40 A) to 1 mV/A (400 A) |
| Resolution: | ±50 mA (40 A) to ±100 mA (400 A) |
| Load Impedance: | > 10 k Ohms and 100 pF |
| Frequency Range (small signal): | DC to 20 kHz (- 3 dB) |
| Phase Shift below 1 kHz, 2 degrees | |
| Temperature Coefficient: ±0.1 percent of reading / ±C | |
| Power Supply: | 9 V Alkaline |
Specifications
| Electrical Characteristics | |
| Current Ranges | 30 A and 300 A ACRMS or ±45 A and 450 A DC |
| AC RMS or DC | ±45 A and 450 A |
| Inrush Current | 600A AC RMS MAX |
| Output Sensitivity | 10 mV/A (30 A) 1 mV/A (300 A) |
| Accuracy | (at +25 drgrees C) (30A range) ±1 percent of reading ±50 mA (300A range) ±1 percent of reading ±300 mA |
| Bandwidth to meet accuracy specification | 1 kHz |
| Phase Shift below 1 kHz | 2 degrees |
| Resolution | ±50 mA (30 A) ±100 mA (300 A) |
| Load Impedance | > 10 k Ohms and ≤100 pF |
| Conductor Position Sensitivity | ±1.5 percent relative to centre reading |
| Frequency Range (small signal) | DC to 20 kHz (- 3 dB) |
| Temperature Coefficient | ±0.1 percent of reading / degrees C |
| Power Supply | 9 V Alkaline, MN1604/PP3 |
| Battery Life | 30 Hours, low battery indicator |
| Working Voltage (see Safety Standards section) | 300 V AC RMS or DC |
| General Characteristics | |
| Maximum Conductor Size | 19 mm diameter |
| Output Connection | Safety BNC connector Supplied with safety 4mm adaptor |
| Output Zero | Manual adjust via thumbwheel |
| Cable Length | 2 metres |
| Operating Temperature Range | -10 to +50 degrees C |
| Storage Temperature Range (with battery removed) | -20 to +85 degrees C |
| Operating Humidity | 15 percent to 85 percent (non-condensing) |
| Weight | 250 g |
| Safety Standards | |
| BS EN 61010-1 | 2001 |
| BS EN 61010-2-032 | 2002 |
| BS EN 61010-031 | 2002 |
| 300 VRMS, Category III, Pollution Degree 2 | |
| Note | Use of the probe on un-insulated conductors is limited to 300 V AC RMS or DC and frequencies below 1 kHz. |
| EMC Standards | BS EN 61236 1998 +A1, A2, & A3 |