Main page content
Fluke 805 FC Handheld Vibration Meter measures vibrations from 10 Hz to 1,00 Hz on the low frequency range and from 4,000 Hz to 20,000 Hz on the high frequency range. The Fluke 805 FC features a four level severity scale for quick reference, exportable data via USB, Fluke Connect capabilities, data logging of up to 3,500 measurements, convenient indication of how much pressure needs to be applied to get accurate readings, and more.
Features
| Characteristics: | Fluke 805 FC Handheld Vibration Meter |
| Advanced sensor design keeps measurement variations based on device angle or contact pressure to a minimum | |
| Dependable data quality at both high and low frequency ranges | |
| Vibration severity scale | |
| Export data via USB | |
| Includes Microsoft Excel trending data templates | |
| Vibration measurement from 10 Hz to 1,000 Hz for velocity, acceleration, and displacement units of measurement | |
| Innovative Crest Factor+ technology provides reliable bearing assessments using direct sensor tip measurements between 4,000 Hz and 20,000 Hz | |
| Unit can compare vibration levels with ISO-10816 severity scales and store results to the Fluke Connect Cloud | |
| Share live video feed of what you are measuring via Fluke Connect Share-Live video call | |
| Intuitive red and green indicators in addition to on screen comments shows the user how much pressure needs to be applied to take measurements | |
| Includes IR Spot measurements | |
| Stores up to 3,5000 measurements | |
| External accelerometer support | |
| Built-in flash light | |
| Large, high resolution screen |
Specifications
| Specifications: | Fluke 805 FC Portable Vibration Meter |
| Vibration Meter | |
| Low frequency range (overall measurement) | 10 Hz to 1,000 Hz |
| High frequency range (CF+ measurement) | 4,000 Hz to 20,000 Hz |
| Severity levels | Good, Satisfactory, Unsatisfactory, Unacceptable |
| Vibration limit | 50 g peak (100 g peak-peak) |
| A/D converter | 16-bit |
| Signal to noise ratio | 80 dB |
| Sampling rate | - |
| Low frequency | 20,000 Hz |
| High frequency | 80,000 Hz |
| Real time clock backup | Coin battery |
| Sensor | |
| Sensitivity | 100 mV / g ± 10% |
| Measurement range | 0.01 g to 50 g |
| Low frequency range (overall measurement) | 10 Hz to 1,000 Hz |
| High frequency range (CF+ measurement) | 4,000 Hz to 20,000 Hz |
| Resolution | 0.01 g |
| Accuracy | At 100 Hz ± 5 % of measured value |
| Amplitude units | |
| Acceleration | g, m/sec2 |
| Velocity | in/sec, mm/sec |
| Displacement | mils, mm |
| Infrared thermometer (temperature measurement) | |
| Range | -20 °C to 200 °C (-4 °F to 392 °F) |
| Accuracy | ±2 °C (4 °F) |
| Focal length | Fixed, at ~3.8 cm (1.5″) |
| External sensor Note: Fluke supports, but does not provide, external sensors. | |
| Frequency range | 10 Hz to 1,000 Hz |
| Bias voltage (to supply power) | 20 V dc to 22 V dc |
| Bias Current (to supply power) | Maximum 5 mA |
| Firmware | |
| Calibration | Factory calibration required |
| External interfaces | USB 2.0 (full speed) communication |
| Data capacity | Database on internal flash memory |
| Upgrade | through USB |
| Memory | Up to 3,500 measurements |
| Radiated emission | |
| Electrostatic discharge: Burst | Standard EN 61000-4-2 |
| Electromagnetic interference | Standard EN 61000-4-3 |
| RE | Standard CISPR 11, Class A |
| Environmental | |
| Operating temperature | -20 °C to 50 °C (-4 °F to 122 °F) |
| Storage temperature | -30 °C to 80 °C (-22 °F to 176 °F) |
| Operating humidity | 10 % to 95 % RH (non-condensing) |
| Operating/ Storage altitude | Sea Level to 3,048 meters (10,000 feet) |
| IP rating | IP54 |
| Vibration limit | 500 g peak |
| Drop test | 1 meter |
| General specifications | |
| Battery type | AA (2) Lithium Iron Disulfide |
| Battery life | 250 measurements |
| Size (L x W x H) | 25.72 cm x 16.19 cm x 9.84 cm (10.13 in x 6.38 in x 3.875 in) |
| Weight | 1.16 kg (2.55 lb) |
| Fluke Connect™ mobile app compatible* | Yes |
| Connectors | USB mini-B 7-pin, external sensor jack (SMB connector) |
*RF connection time (binding time) can take up to 1 minute.
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.