Main page content
Fluke 28 II Ex/ETL Intrinsically Safe True RMS Digital Multimeter 4017176
4017176
QVT-2012092848110062161
Fluke 28 II Ex/ETL Intrinsically Safe True RMS Digital Multimeter 4017176 is capable of being used both inside and outside ATEX zones 1, 2, 21, or 22 to get the job done with one instrument. Extremely durable meter to handle any conditions Mother Nature might throw its way. The Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter measures AC/DC Voltage, AC/DC Current, Resistance, Conductance, Diode Test, Duty Cycle, Capacitance, Frequency, and Temperature.
Features
| Characteristics | Fluke 28 II Ex/ETL Intrinsically Safe True RMS Digital Multimeter 4017176 |
| Sealed IP67 rated case | |
| Dustproof per IEC60529 IP6x | |
| Waterproof per IEC60529 IPx7 | |
| Meets IEC Overvoltage Electrical Safety Standard No. 61010-1:2001 | |
| Reversible holster | |
| Auto and manual ranging | |
| Input Alert | |
| Min/Max-Average and Peak capture | |
| Backlit keypad buttons | |
| Large display | |
| Long battery life | |
| Optional magnetic hanger |
Specifications
| Specifications | Fluke 28 II Ex/ETL Intrinsically Safe True RMS Digital Multimeter 4017176 | |
| Basic Accuracy Specs | ||
| Accuracy specifications are show as +/- (% of reading + number of digits) | ||
| DC Voltage | Range | 0.1 mV to 1000 V |
| Accuracy | ±0.05 % + 1 | |
| AC Voltage | Range | 0.1 mV to 1000 V |
| Accuracy | ±0.7 % +4 | |
| DC Current | Range | 0.1 μA to 10 A |
| Accuracy | ±0.2 % + 4 | |
| AC Current | Range | 0.1 μA to 10 A |
| Accuracy | ±1.0 % + 2 | |
| Resistance | Range | 0.1 Ω to 50 MΩ |
| Accuracy | ±(0.2 % + 1) | |
| Conductance | Range | 60.00 nS |
| Accuracy | ± (1.0 % + 10) | |
| Diode Test | Range | 2.0 V |
| Accuracy | ± (2.0 % + 1) | |
| Duty Cycle | Range | 0.0 % to 99.9 % |
| Accuracy | Within ±(0.2 % per kHz + 0.1 %) for rise times <1 µs | |
| Capacitance | Range | 10 nF to 9999 μF |
| Accuracy | ± (1.0 % + 2) | |
| Frequency | Range | 0.5 Hz to 199.99 kHz |
| Accuracy | ± (0.005 % + 1) | |
| Temperature | Range | -200 °C to +1090 °C (-328 °F to +1994 °F) |
| Accuracy | ± (1.0 % + 10) °C [± (1.0 % + 10) °F] | |
| Display Counts | 6000 counts/19,999 counts in high-resolution mode | |
| Peak Capture | Record transients up to 250 us | |
| Min/Max/Avg Recording | Display signals up to approximately 100 ms | |
| Safety Certifications | ||
| ATEX | II 2 G Ex ia IIC T4 Gb | |
| II 2 D Ex ia IIIC T130 °C Db | ||
| I M1 Ex ia I Ma | ||
| NEC-500 | Class I, Div 1, Groups A-D, 130 °C | |
| IEXEx | Ex ia IIC T4 Gb | |
| Ex ia IIIC T130 °C Db | ||
| Ex ia I Ma | ||
| GOST R Ex (Pending) | Overvoltage protection: Measurement Category III, 1000V, Pollution Degree 2 | |
| Measurement Category IV, 600V, Pollution Degree 2 | ||
| IP rating: IP67 | ||
| General | Power | Three AAA Batteries |
| Battery Life | 400 hours | |
| Display | LCD, with backlight | |
| External protection | Rubber holster | |
| Warranty | Three years | |
| Dimensions (with holster) | 2.5" x 3.93" x 7.8" (6.35 x 10.0 x 19.81cm) | |
| Weight (with holster) | 1.54lbs (698.5g) | |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Resources