Main page content
Fieldpiece SMAN360 3-Port Digital Manifold with Vacuum Gauge is an advanced digital manifold with integrated vacuum gauge alarms, stopwatch, rate indicator, and simultaneous display of all measurements. The Fieldpiece SMAN360 features calculation of superheat, subcooling, target superheat, vapor saturation, and liquid saturation, 3 hose connection ports, an over-sized illuminated display, viewing glass, and compatibility with 45 different refrigerants (update-able via USB).

Fieldpiece SMAN Digital Refrigerant Manifold SM380V Data Sheet.pdf

Fieldpiece SM380V User Manual Data Sheet.pdf
Features
Rugged Construction:
- Heavy-duty, impact resistant overmold casing
- Equipped with reinforced hook
- Water resistant to IP54
- Impact resistant screen
- Strategically placed thermocouple ports
- Hermetically sealed sight glass
Data Logging Capabilities:
- Stores up to 9 jobs internally
- Easy download via USB port
- Displays percentage of free storage space before logging begins
- Logs up to 7 days (168 continuous hours)
Tightness Test Function:
- Check for leaks after repairs or installations
- View pressure differential over time
- Timer tracks duration of test
- Temperature compensated with SL temp to avoid false positives
Customizable Features:
- Adjust auto power off duration
- Adjust back light duration
- Set high and low vacuum alarms
- Select each unit of measurement individually
Wireless Capabilities:
- View wireless and scale readings
- Pipe Temperatures: Place pipe clamps in desired location and view instantaneous readings on your screen
- Refrigerant Usage: Monitor and record live refrigerant usage for precise recovery, charging and documentation
- Indoor Air Temperatures: View live air measurements and calculations on your SMAN while making adjustments
Job Link System App Compatibility:
- View measurements on SMAN and/or in Job Link App
- Monitor and record refrigerant weight
- Direct 350 ft. wireless range (no transmitter needed)
- Document work and provide professional reports via app
Specifications
| Specifications: | Fieldpiece SMAN Digital Refrigerant Manifold SM380V 3 Port and Micron Gauge |
| Pressure | |
| Connector Type | Standard 1/4" NPT male flare fitting |
| Range | 29” HgV to 580 Psig (English), 74 cmHgV to 0 to 4000KPa (Metric) |
| Resolution | 0.1 psi/inHg; 1 kPa/cmHg |
| Accuracy | 29” HgV to 0” HgV: ±0.2” HgV 74 cmHgV to 0 cmHgV: ±1 cmHgV 0 to 200 Psig: ±1 Psi; 0 to 1378 KPa: ±7 KPa; 0 to 1.378MPa: ±0.007MPa; 0 to 13.78 bar ±0.07 bar 200 to 580 Psig: ±(0.3% of reading+1 Psig); 1378 to 4000KPa: ±(0.3% of reading+7 Kpa); 1.378 to 4.000MPa: ±(0.3% of reading+0.007MPa); 13.78 to 40.00bar: ±(0.3% of reading +0.07bar) |
| Maximum overload pressure | 800 psig |
| Units | Psig, kPa, MPa, bar, inHg, and cmHg |
| Microns for Vacuum | |
| Connector Type | Standard 1/4" NPT male flare fitting |
| Range | 50 to 9999 microns of mercury |
| Resolution | 1 micron (0 to 2000 microns), 250 microns (2001 to 5000 microns), 500 microns (5001 to 8000 microns), 1000 microns (8001 to 9999 microns) |
| Accuracy | ±(5% of reading + 5 microns), 50 to 1000 microns |
| Maximum Overload pressure | 580 psig |
| Units | Microns of mercury |
| Temperature | |
| Sensor type | Type K thermocouple |
| Range | -50ºF to 257ºF (-46ºC to 125ºC) limited by the thermocouple specification. |
| Range | Display Range is -95°F to 999.9°F (-70°C to 537.0°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±(1.0°F) -95°F to 200°F; ±(0.5°C) -70°C to 93°C ±(2.0°F) 200°F to 999.9°F; ±(1.0°C) 93°C to 537.0°C |
| General | |
| Display size | 5 inches (diagonal) |
| Backlight | Blue (adjustable duration) |
| Radio Frequency | 2.4 GHz |
| Wireless Range | 350 feet (106 meters) line of sight Distance decreases through obstructions |
| Micro-USB Port | For extracting logged data or updating firmware. |
| Battery | 6 x AA (Battery life below based on alkaline type) |
| Battery life | 350 hours (without vacuum, backlight, and wireless) |
| Low battery indication | Icon displayed when the battery voltage drops below the operating level |
| Auto Shut off | 30 minutes of inactivity (adjustable) |
| Operating environment | 32°F to 122°F (0°C to 50°C) at <75% relative humidity |
| Storage temperature | -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) |
| Temperature coefficient | 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C), per 1.8°F (32°F to 64°F, 82°F to 122°F) |
| Over range | "OL" or "-OL" is displayed |
| Weight | 4.03 lbs (1.38 kg) |
| Water Resistant | Designed to IP54 |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Resources

Fieldpiece SMAN Digital Refrigerant Manifold SM380V Data Sheet.pdf

Fieldpiece SM380V User Manual Data Sheet.pdf
Fieldpiece SM380V SMAN Digital Refrigerant Manifold
Dataloging on the New SMANs Digital Manifold
Adjusting the Customizable options on the new SMANs
Syncing your Job Link Tools to the New SMANs Digital Manifold
Connect your New SMAN to the Job Link App