Fieldpiece HS33 Expandable Stick Multimeter for HVAC/R is a manual ranging meter that measures Continuity, Capacitance, Alternating Current/Direct Current Volts, Diode Test, Resistance, and Temperature. This meter comes with a magnetic holster for hands-free operation. This tester has Non-contact voltage capabilities as well as an Auto-off function.
Features
| Characteristics: | Fieldpiece HS33 HVAC Expandable Stick Multimeter |
| Minimum/Maximum and Data hold functionality | |
| Silicone leads with separable probe tips | |
| Durable ABS Case | |
| Magnetic Holster | |
| Compact design | |
| Auto-off |
Specifications
| Specifications | Fieldpiece HS33 Expandable Manual Ranging Stick Multimeter for HVAC/R | |
| Diode Test | Test current | ~1.0mA |
| Accuracy | ±(1.5% rdg + 3 dgts) | |
| Open circuit volts | 3.0VDC typical | |
| Overload protection | 500VDC or AC rms | |
| Continuity | Audible indication | Less than 100O |
| Response time | 100ms (Green LED will be on continuously) | |
| Overload protection | 500VDC or AC rms | |
| Capacitance | Range | 200µF |
| Resolution | 0.1µF | |
| Accuracy | ±(3% rdg + 5 dgts) | |
| Overload protection | 500VDC or AC rms | |
| DC Volts | Ranges | 200mV, 2000mV, 200V |
| Resolution | 0.1mV | |
| Accuracy | ±(0.5% rdg + 1 dgt) | |
| Input impedance | 560kO on V inputs, 10MO on mV input | |
| Overload protection | 600VDC or AC rms, 500VDC/350VAC rms 15 sec on 200mV range | |
| Transient protection | 6kV for 10µ sec | |
| AC Volts (50Hz - 500Hz) | Ranges | 200mV, 200V, 600V |
| Resolution | 0.1mV | |
| Accuracy | ±(1.2% rdg + 3 dgts) ±(2.0% rdg + 5 dgts) on 600V range | |
| Input impedance | 560kO on V input, 10MO on mV input | |
| Overload protection | 600V DC or AC rms | |
| Transient protection | 6kV for 10µ sec | |
| Resistance | Ranges | 200O, 200kO |
| Resolution | 0.1O | |
| Accuracy | ±(1.0% rdg + 4 dgts) | |
| Open circuit volts | 0.3VDC typical, (3.0VDC on 200O range) | |
| Overload protection | 500VDC or AC rms | |
| Temperature | Range | -30 to 200°F (-34 to 93°C) |
| Resolution | 0.1°F/°C | |
| Accuracy | ±1°F, 32 to 120°F (0 to 48°C), ±1% + 1.5°F, -4 to 200°F (-20 to 93°C), ±2% + 3°F, -30 to -4°F (-34 to -20°C) | |
| Sensor type | K-type thermocouple | |
| Overload protection | 60 VDC or 30 VAC rms | |
| Display | 3½ digit liquid crystal display (LCD) with a maximum reading of 1999 | |
| Overrange | "OL" mark indication | |
| Auto power off | 60 minutes | |
| Operating enviroment | 32 to 122°F (0 to 50°C) at <70% R.H. | |
| Storage temperature | -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed | |
| Accuracy | Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity | |
| Temperature Coefficient | 0.1×(specified accuracy) per °F/°C. (32 to 64°F (0 to 18°C), 82 to 122°F (28 to 50°C)) | |
| Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 | |
| Battery life | 300 hours typical with alkaline | |
| Accessories | One pair test leads, one pair alligator clips, k-type thermocouple (HS33), 9V battery (installed), and operating instructions | |
| Safety | UL, CE, Cat III 600V, UL3111, IEC/EN61010-1, C-Tick certified | |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.