Main page content
Fieldpiece DR58 Heated Diode Refrigerant Leak Detector with High Sensitivity Sensor
DR58
QVT-2021052101571053951
Fieldpiece DR58 Heated Diode Refrigerant Leak Detector High Sensitivity
Since it’s a Fieldpiece, the DR58 Heated Diode Refrigerant Leak Detector is full of the features you need. It’s also designed to handle the abuse that most leak detectors can’t with an impact resistant IP54-certified body that fits easily in your hand.
Sniffing leaks at less than 0.03 oz/yr (1g/a), the DR58 detects all HFC, CFC, HCFC, HFO and blended refrigerants with superior sensitivity at detecting R410A refrigerant. On the DR58’s new, bright backlit LCD screen you’ll see easy-to-read bar graphs, numeric readings and customizable dual alarms. No more guessing about what’s leaking. Also, it can both automatically and manually zero to refrigerant gas concentrations giving you total control.
The DR58 boasts an 18-hour battery life that’ll last longer than you will on the job site. Yes, it’s built to perform. Soap bubble solutions can take several minutes to form visible bubbles and messy UV dyes can take several hours to travel through a running system.
What's Included:
- (1) Heated Diode Refrigerant Leak Detector – DR58
- (5) Replacement Filtered Tips – RFT6
- (1) Blow-Molded Case
- (1) Heated Diode Sensor – RHD1
Features
Characteristics:
- Sensor Type: Heated diode
- Sensor Life: 300 hours typical
- Sensitivity Levels: High, medium, low (selectable)
- Maximum Sensitivity: 0.03 oz/yr (1g/a), stationary; 0.1 oz/yr (3g/a), in motion
- Detection Feedback: Red tip LED, LCD bar graph, LCD digits, beeper
- Refrigerants: HFC, HCFC, CFC, HFOs, and blends
- Response Time: <1 seconds typical
- Recovery Time: <10 seconds typical
- Battery Type: 3.7 VDC (nominal) 2600mAh, non-replaceable
- Charge Time: 6 hours typical with included charger.
- Battery Life: 18 hours typical, backlight off
- Auto Power Off: 10 minutes without detection or button press
- Operating Environment: 32°F to 104°F (0°C to 40°C); < 75% RH (non-condensing)
- Storage Temperature: -4°F to 140°F (-20°C to 60°C); < 80% RH
- Weight: 14 oz (400g)
- Water Resistance: Designed to IP54
Specifications
| Specifications: | Fieldpiece DR58 Heated Diode Refrigerant Leak Detector High Sensitivity |
| General Specifications | |
| Sensor Type: | Heated diode |
| Sensor Life: | 300 hours typical |
| Sensitivity Levels: | High, medium, low (selectable) |
| Maximum Sensitivity: | 0.03 oz/yr (1g/a), stationary; 0.1 oz/yr (3g/a), in motion |
| Detection Feedback: | -Red tip LED, LCD bar graph, LCD digits, beeper |
| Refrigerants: | HFC, HCFC, CFC, HFOs, and blends |
| Response Time: | <1 seconds typical |
| Recovery Time: | <10 seconds typical |
| Battery Type: | 3.7 VDC (nominal) 2600mAh, non-replaceable |
| Charge Time: | 6 hours typical with included charger. |
| Battery Life: | 18 hours typical, backlight off |
| Auto Power Off: | 10 minutes without detection or button press |
| Operating Environment: | 32°F to 104°F (0°C to 40°C); < 75% RH (non-condensing) |
| Storage Temperature: | -4°F to 140°F (-20°C to 60°C); < 80% RH |
| Weight: | 14 oz (400g) |
| Water Resistance: | Designed to IP54 |
| US Patent: | www.fieldpiece.com/patent |