Main page content
Amprobe 34XR-A TRMS Digital Multimeter with Backlight and Temperature
2727795
QVT-2007053012284530615
Amprobe 34XR-A Digital Multimeter is a RMS Digital Multimeter with temperature and backlight capabilities. Amprobe 34XR-A is designed for maintenance, repair, and installation of electrical and electro-mechanical equipment. This multimeter is a great tool for contractors and field service technicians.
Features
| Chracteristics: | Amprobe 34XR-A TRMS Digital Multimeter with Backlight and Temperature |
| Frequency to 40 Megahertz, temperature to 1832 Degrees F, and capacitance to 4000 μF | |
| Warning tones | |
| 1000 Volt/750 Volt dc/ac currents | |
| Safety fused for up to 10 Amps ac/dc current | |
| Resistance to 40 mA loop | |
| Stability beeper | |
| Buttons to display the min/max and to freeze the current data reading | |
| UL (CULUS) registered | |
| Auto-off | |
| Magnetic holster that has a hanging strap included | |
| Separate access door for fuse and battery | |
| CAT III 600 V, CAT II 1000 Volt rated | |
| 3 year warranty included |
Specifications
| Specifications: | Amprobe 34XR-A Digital Multimeter |
| Voltage DC | 1000 V |
| mV AC | TRMS |
| DC Voltage | Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V Accuracy all ranges: +/- (0.5 % rdg + 1 dgt) Resolution 100 μV |
| AC Voltage (45 Hz to 2 kHz) True RMS | Ranges 400 mV, 4 V, 40 V, 400 V, 750 V Accuracy 400 mV range, 45 to 100 Hz: +/- (1.2 % rdg + 8 dgts) Accuracy 750 V range: 45 to 1 kHz: +/- (2.0 % rdg + 8 dgts) Accuracy All other ranges, 45 to 500 Hz: +/- (1.2 % rdg + 8 dgts) Accuracy All other ranges, 500 to 2 kHz: +/- (2.0 % rdg + 8 dgts) Resolution 100 μV AC coupled True RMS specified from 5 % to 100 % of range |
| DC Current | Ranges 400 μA, 4 mA, 40 mA, 300 mA, 10 A Accuracy 400 μA to 300 mA ranges: +/- (1.0 % rdg + 1 dgt) Accuracy 10 A range: +/- (2.0 % rdg + 3 dgts) Resolution 0.1 μA |
| AC Current (45 Hz to 1 kHz) True RMS | Ranges 400 μA, 4 mA, 40 mA, 300 mA, 10 A Accuracy 400 μA to 300 mA ranges: +/- (1.5 % rdg + 8 dgts) Accuracy 10 A range: +/- (2.5 % rdg + 10 dgts) Resolution 0.1 μA |
| Resistance | Ranges 400 Ω, 4 kΩ, 40 kΩ, 400 kΩ, 4 MΩ, 40 MΩ, Accuracy 400, 4 k, 40 k, 400 k, 4 MΩ ranges: +/- (1.0 % rdg + 4 dgts) Accuracy 40 MΩ range: +/- (2.0 % rdg + 5 dgts) Resolution 100 mΩ |
| Capacitance | Ranges 4 μF, 40 μF, 400 μF, 4000 μF Accuracy 4 μF range: +/- (5.0 % rdg + 10 dgts) Accuracy 40 μF, 400 μF ranges: +/- (5.0 % rdg + 5 dgts) Accuracy 4000 μF range: +/- (5.0 % rdg + 15 dgts) Resolution 1 nF |
| Temperature | Ranges -20 to 1000 Degrees C, -4 to 1832 Degrees F Accuracy -20 to 10 Degrees C: +/- (2.0 % rdg + 4 Degrees C ) Accuracy 10 to 200 Degrees C: +/- (1.0 % rdg + 3 Degree C ) Accuracy 200 to 1000 Degrees C: +/- (3.0 % rdg + 2 Degrees C ) Accuracy -4 to 50 Degrees F: +/- (2.0 % rdg + 8 Degrees F) Accuracy 50 to 400 Degrees F: +/- (1.0 % rdg + 6 Degrees F) Accuracy 400 to 1832 Degrees F: +/- (3.0 % rdg + 4 Degrees F) Resolution 1 Degree C, 1 Degree F |
| Frequency | Ranges 4 kHz, 40 kHz, 400 kHz, 4 MHz, 40MHz Accuracy all ranges: +/- (0.1 % rdg + 3 dgts) Resolution 1 Hz |
| Duty Cycle | Ranges 0 to 90 % Accuracy 5 V logic: +/- (2.0 % rdg + 5 dgts) Frequency Range 40 Hz to 20 kHz |
| Continuity | Audible Indication < 35 ? |
| Diode Test | Test Current 1.2 mA (approximate) Open Circuit Volts 3.0 V dc typical |
| Overload Protection | AC/DC Voltage All ranges 1000 V dc or 750 V ac rms AC/DC Current μA/mA input: 0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm) AC/DC Current 10 A input: 10 A /1000 V fast-blow ceramic 10 x 38 mm (10 A for 4 minutes maximum followed by a 12 minute cooling period) |
| Autoranging; Display | 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph |
| Display Update Rate | 2/sec, nominal |
| Power Battery | 9 V NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life | 200 hrs typical (alkaline) frequent use of backlight will decrease battery life |
| Operating Temperature | 0 to 45 Degrees C at < 70 % R.H. |
| Weight without holster, including battery) | (1 lb (400 gr)) |
| Storage Temperature | -20 to 60 Degrees C, 0 to 80 % R.H. with battery removed from meter |
| Dimensions | 7.75" x 3.55" x 2.4" (196 x 92 x 60mm) |
| Voltage AC | 750 TRMS AC |
| Basic DC Accuracy | 0.5% |
| DC Current, fused | 10 A |
| AC Current, fused | 10 A TRMS |
| Resistance | 40M? |
| Capacitance | 4000 μF |
| Frequency | 40 MHz |
| Temperature | 1832 Degrees F/1000 Degrees C |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.