Main page content
Amprobe 30XR-A Digital Multimeter is a standard manual ranging multimeter with the standard sensing capabilities. This multimeter includes Voltect- a built-in non-contact voltage tester. The 30XR-A has all the basic functions for automotive, residential and education applications.
Features
| Chracteristics: | Amprobe 30XR-A Digital Multimeter with NCV Detection |
| Non-contact voltage tester that tests up to a 600 Volt ac current | |
| Magnetic holster that has a hanging strap included | |
| Ac/dc current testing up to 600 Volts | |
| Safety fused for up to 10 Amps ac/dc current | |
| Resistance to 20 mA loop | |
| Stability beeper | |
| 1.5 Volt / 9 Volt battery tested | |
| Buttons to display the min/max and to freeze the current data reading | |
| Separate access door for fuse and battery | |
| CAT III 300 V, CAT II 600 Volt rated | |
| UL (CULUS) registered | |
| 1 year warranty included |
Specifications
| Specifications: | Amprobe 30XR-A Digital Multimeter |
| DC Voltage | Ranges 200 mV, 2 V, 20 V, 200 V, 600 V Accuracy all ranges +/- (1 % rdg + 1 dgt) Resolution 100 μV Input Impedance 10 MΩ |
| AC Voltage (45 Hz to 500 Hz | Ranges 200 mV, 2 V, 20 V, 200 V, 600 V Accuracy all ranges +/- (1.5 % rdg + 4 dgts) Resolution 100 μV Input Impedance 10 MΩ |
| DC Current | Ranges 200 μA, 2 mA, 20 mA, 200 mA, 10 A Accuracy 200 μA to 200 mA ranges +/- (1.5 % rdg + 1 dgt) Accuracy 10 A range +/- (2.0 % rdg + 3 dgts) Resolution 0.1 μA Voltage Burden (Max) 200 μA range 1 mV/μA Voltage Burden 2 mA range 100 mV/1mA Voltage Burden 20 mA range 13 mV/1 mA Voltage Burden 200 mA range 4.6 mV/1 mA Voltage Burden 10A range 40 mV/1 A |
| AC Current (45 Hz to 500 Hz) | Ranges 200 μA, 2 mA, 20 mA, 200 mA, 10 A Accuracy 200 μA to 200 mA ranges +/- (2.0 % rdg + 4 dgts) Accuracy 10A range +/- (2.5 % rdg + 4 dgts) Resolution 0.1 μA Voltage Burden See DC Current |
| Resistance | Ranges 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ Accuracy 200 Ω to 200 kΩ ranges +/- (1.0 % rdg + 4 dgts) Accuracy 2 MΩ range +/- (1.5 % rdg + 4 dgts) Accuracy 20 MΩ range +/- (2.0 % rdg + 5 dgts) Resolution 100 mΩ Open Circuit Voltage 200 Ω range 3.0 V dc Open Circuit Voltage All other ranges 0.3V dc typical |
| Continuity | Audible Indication 75 Ω +/- 25 Ω Response Time 100ms |
| Diode Test | Test Current 1.0 mA (approximate) Accuracy +/- (1.5 % rdg + 3 dgts) Resolution 0.001 V Open Circuit Volts 3.0 V typical |
| Battery Test | Ranges 1.5 V, 9 V Accuracy +/- (3.5 % rdg + 2 dgts) Resolution 1 mV, 10 mV Load Test Current 1.5 V range 150 mA typical Load Test Current 9 V range 5 mA typical |
| Non-Contact Voltage Detector (NCV) | AC Volts 70 to 600 V ac Red LED and Audible Indicator |
| Overload Protection | AC/DC Voltage 400 mV range 600 V dc or 600 V ac rms 15 sec All other ranges 600 V dc or 600 V ac rms AC/DC Current uA/mA input F 0.25 A/ 600 V Min. I.R. 30 kA (6.3 x 32 mm)10 A input F 10A / 600V, Min. I.R. 100 kA, (10 x 38 mm) (10 A for 4 minutes maximum followed by a 12 minute cooling period) Resistance 600 V dc or 600 V rms Continuity 600 V dc or 600 V ac rms Diode Test 600 V dc or 600 V ac rms Battery Test 600 V dc or 600 V ac rms |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Resources