 TPI 712 Combustion Analyzer with rechargeable Ni-MH battries, and with optional PC interface. All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selection during start up enable tests to be performed quickly without requiring extra set-up time after initial startup.

TPI Instruments 712 Combustion Analyzer also uses the last selected fuel as the default setting. This feature prevents the need to perform fuel selection every time the analyzer is turned on.

The TPI 712 Combustion Analyzer Contents: 712 Combustion Analyzer, A774 Silicone Tubing, A787 Soft Carrying Case, A770 Flue Probe, A763 Mini pump, A603 Brass Hose Barb Fitting (2), A611 Gas Valve Pressure Adapter, A776 Static Tip (2), A791 Adapter tubing, GK11M K-type thermocouple. Free ground shipping within continental US.
 |
| TPI 712 Combustion Analyzer Applications: |
| |
 Tuning of residential and furnaces and domestic boilers
 |
| |
 Ambient and stack testing for CO
 |
| |
 CO safety measurements in and around combustion sources
 |
| |
 Temperature checking, including superheat and hydronic differential temperatures
 |
| |
 Detecting gas leak in gas lines and around gas fueled appliances. Dual input differential manometer with 3 selectable units of measure: kPa, mBar,inH20
 |
| TPI 712 Combustion Analyzer Characteristics: |
| |
 Calculates combustion efficiency
 |
| |
 Built-in differential thermometer and built in differential manometer with 0.001” H2O resolution
 |
| |
 Pump driven for fast response
 |
| |
 Store function to save up to 50 readings
 |
| |
 Will not shut off if 15 ppm CO is present for increased safety
 |
| |
 Push on fittings for fast and easy use
 |
| |
 Ten selectable fuels
 |
| |
 Large easy to read backlit display
 |
| |
 Optional A740 IR printer available for hard copies of test results
 |
| 712 Contents: |

 |
| |
 712 Combustion Analyzer
 |
| |
 A787 Soft Carrying Case
 |
| |
 A763 Mini pump
 |
| |
 A603 Brass Hose Barb Fitting (2)
 |
| |
 GK11M K-type thermocouple
 |
| |
 A611 Gas Valve Pressure Adapter
 |
| |
 A774 Silicone Tubing
 |
| |
 A776 Static Tip (2)
 |
| |
 A770 Flue Probe
 |
| |
 A791 Adapter tubing
 |
| TPI 712 Combustion Analyzer Specifications: |
| Instrument |

 |
| Operating Temperature Range |
 14 degrees F to +122 degrees F (-10 degrees C to +50 degrees C)
 |
| Battery / Battery Life |
 Rechargeable Ni-MH / > 6 Hours
115V or 230V : 50/60 Hz AC
 |
| Fuels |
 Natural Gas, LPG, Light Oil, Heavy
Bituminous Coal, Anthracite Coal,
Coke, Butane, Wood, Bagass
 |
| Display |
 3 Line Backlit LCD w/ annunciators
 |
| Data Storage |
 50 sets of readings
 |
| Time & Date |
 24 Hour Real Time Clock
 |
| Dimensions |
 7.8 inch x 3.5 inch x 2.4 inch
 |
| Weight |
 1.1lbs
 |
| Gases |

 |
| Oxygen |

 |
| Range |
 0-25 percent
 |
| Resolution |
 0.1 percent
 |
| Accuracy |
 +/- 0.3 percent
 |
| Carbon Monoxide |

 |
| Range |
 0-10,000 ppm
 |
| Resolution |
 1 ppm
 |
| Carbon Dioxide |

 |
| Accuracy |
 Calculated
 |
| CO/CO2 Ratio |

 |
| Range |
 0-0.999
 |
| Resolution |
 0.001
 |
| Combustion Eff. |

 |
| Range |
 0-100 percent
 |
| Resolution |
 0.1 percent
 |
| Temperature Measurement |

 |
| Input Type |
 K-Type thermocouple
 |
| Range |
 -58 degrees F to 1832 degrees F (-50 degrees C to 1000 degrees C)
 |
| Resolution |
 1 degrees F (1 degrees C)
 |
| Accuracy |
 +/- (0.3 percent of rdg + 2 degrees F) or +/- (0.3 percent of rdg + 1 degrees C)
 |
| Units of Pressure |
 Mbar, kPa & inH2O
 |
| Pressure Measurement |

 |
| Selectable Ranges |
 Mbar, kPa and inH2O
 |
| Range |
 -120 inH2O to 120 inH2O
 |
| Resolution |
 0.001 inH2O
 |
| Accuracy |
 +/- 0.5 percent fsd
 |
| Data Storage |
 10 sets of readings
 |
| Data Logging |
 400 sets of readings
 |
| Single Logging |
 150 sets of readings
 |