Datasheet: TPI-709R |
 |
| TPI 709R Combustion Efficiency Analyzer Description: |
 TPI 709R Combustion Efficiency Analyzer with Differential Manometer. All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selection during start up enable tests to be performed quickly without requiring extra set-up time after initial startup.

The TPI 709R Combustion Efficiency Analyzer also use the last selected fuel as the default setting. This feature prevents the need to perform fuel selection every time the analyzer is turned on.

The TPI 709R Combustion Efficiency Analyzer Contents: 709 Combustion Analyzer, A774 Silicone Tubing, A787 Soft Carrying Case, A770 Flue Probe, A763 Mini pump, protection filter, GK11M K-type thermocouple. Free ground shipping within continental US.
 |
| TPI 709R Combustion Efficiency Analyzer Applications: |
| |
 Tuning of residential and furnaces and domestic boilers
 |
| |
 Ambient and stack testing for CO
 |
| |
 CO safety measurements in and around combustion sources
 |
| |
 Temperature checking, including superheat and hydronic differential temperatures
 |
| |
 Dual input differential manometer
 |
| TPI 709R Combustion Efficiency Analyzer Characteristics: |
| |
 Calculates combustion efficiency
 |
| |
 Built-in differential thermometer and built in differential manometer with 0.001” H2O resolution
 |
| |
 Pump driven for fast response
 |
| |
 Store function to save up to 50 readings
 |
| |
 Will not shut off if 15 ppm CO is present for increased safety
 |
| |
 Push on fittings for fast and easy use
 |
| |
 Ten selectable fuels
 |
| |
 Large easy to read backlit display
 |
| |
 Optional A740 IR printer available for hard copies of test results
 |
| |
 709 Combustion Analyzer
 |
| |
 A787 Soft Carrying Case
 |
| |
 A763 Mini pump
 |
| |
 Protection filter
 |
| |
 GK11M K-type thermocouple
 |
| |
 A774 Silicone Tubing
 |
| 709R Contents: |
 709 Combustion Analyzer, A774 Silicone Tubing, A787 Soft Carrying Case, A770 Flue Probe, A763 Mini pump, protection filter, GK11M K-type thermocouple.
 |
| TPI 709R Combustion Efficiency Analyzer Specifications: |
| Instrument |

 |
| Operating Temperature Range |
 14 degrees F to +122 degrees F (-10 degrees C to +50 degrees C)
 |
| Battery / Battery Life |
 Rechargeable Ni-MH / > 6 Hours
115V or 230V : 50/60 Hz AC
 |
| Fuels |
 Natural Gas, LPG, Light Oil, Heavy
Bituminous Coal, Anthracite Coal,
Coke, Butane, Wood, Bagass
 |
| Display |
 3 Line Backlit LCD w/ annunciators
 |
| Data Storage |
 50 sets of readings
 |
| Time & Date |
 24 Hour Real Time Clock
 |
| Dimensions |
 7.8 inch x 3.5 inch x 2.4 inch
 |
| Weight |
 1.1lbs
 |
| Gases |

 |
| Oxygen |

 |
| Range |
 0-25 percent
 |
| Resolution |
 0.1 percent
 |
| Accuracy |
 +/- 0.3 percent
 |
| Carbon Monoxide |

 |
| Range |
 0-10,000 ppm
 |
| Resolution |
 1 ppm
 |
| Carbon Dioxide |

 |
| Accuracy |
 Calculated
 |
| CO/CO2 Ratio |

 |
| Range |
 0-0.999
 |
| Resolution |
 0.001
 |
| Combustion Eff. |

 |
| Range |
 0-100 percent
 |
| Resolution |
 0.1 percent
 |
| Temperature Measurement |

 |
| Input Type |
 K-Type thermocouple
 |
| Range |
 -58 degrees F to 1832 degrees F (-50 degrees C to 1000 degrees C)
 |
| Resolution |
 1 degrees F (1 degrees C)
 |
| Accuracy |
 +/- (0.3 percent of rdg + 2 degrees F) or +/- (0.3 percent of rdg + 1 degrees C)
 |
| Units of Pressure |
 Mbar, kPa & inH2O
 |
| Pressure Measurement |

 |
| Selectable Ranges |
 Mbar, kPa and inH2O
 |
| Range |
 -120 inH2O to 120 inH2O
 |
| Resolution |
 0.001 inH2O
 |
| Accuracy |
 +/- 0.5 percent fsd
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |