Datasheet: Protek-B4004 |
 |
| Protek B4004 True RMS Bench Multimeter Description: |
 Protek B4004 True RMS Bench Multimeter features MIN/MAX, Peak MIN/MAX and Relative modes. This True RMS bench multimeter provides Back lit display, Auto power off and Auto/Manual ranging. Product Discontinued. Replaced by DM-1140B.
 |
| Protek B4004 True RMS Bench Multimeter Characteristics: |
| |
 AC line or Battery operated
 |
| |
 0.05% DC V Accuracy
 |
| |
 Measures Frequency to 220MHz
 |
| |
 MIN/MAX, Peak MIN/MAX and Relative modes
 |
| |
 Capacitance, and Temperature measurements
 |
| |
 Back lit display, Auto power off and Auto/Manual ranging
 |
| |
 True RMS AC Volts and Amps measurements
 |
| |
 Optically isolated RS232 interface
 |
| Includes: |
 Test leads, Operating manual, RS-232 cable to USB cable and PC Link software, Temp adapter & thermocouple
 |
| |
 Can be used with clamp current tranducers Protek 601C or 602C for high current measurements
 |
| Protek B4004 True RMS Bench Multimeter Specifications: |
| DC Voltage Ranges |
 200mV, 2V, 20V, 200V and 1000V
 |
| DC Voltage Best Resolution |
 10μV
 |
| DC Voltage Accuracy |
 +/-(0.05% +6d)
 |
| DC Voltage Input Impedance |
 10MΩ
 |
| DC Voltage Overload Volts |
 1000V DC or 750V AC RMS
 |
| AC Voltage Ranges |
 200mV, 2V, 20V, 200V, and 750V
 |
| AC Voltage Best Resolution |
 10μV
 |
| AC Voltage Accuracy |
 +/-(0.5% + 30) 40Hz to 60Hz
+/-(1.0% +30d) 60Hz to 5KHz
+/-(2.0% + 30d) 5KHz to 10KHz
 |
| AC Voltage Input Impedance |
 10MΩ
 |
| AC Voltage Overload Volts |
 1000V DC or 750V AC RMS
 |
| DC Current Ranges |
 200μA, 2000μA, 20μA, 200mA, 10A
 |
| DC Current Best Resolution |
 10nA
 |
| DC Current Accuracy |
 +/-(0.15% + 15d)
 |
| DC Current Overload protection |
 0.3A /250V and 10A/250V fuse
 |
| AC Current Ranges |
 200μA, 2000μA, 20mA, 200mA, 10A
 |
| AC Current Best Resolution |
 10nA
 |
| AC Current Accuracy |
 +/-(1.0% + 30d) 60hz to 1KHz;
+/-(1.2% + 30d) 1KHz to 5KHz
 |
| AC Current Overload protection |
 0.3A /250V and 10A/250V fuse
 |
| Resistance Ranges |
 200Ω, 2KΩ, 20KΩ, 200KΩ, 2MΩ, 20MΩ and 200MΩ
 |
| Resistance Best Resolution |
 10mΩ
 |
| Resistance Accuracy |
 +/-(0.1% + 10d) 200Ω to 2MΩ ranges
+/-(0.5% + 10d) 20MΩ range
+/-(2.0% + 10d) 200MΩ range
 |
| Logic Frequency Ranges |
 20Hz to 220MHz
 |
| Logic Frequency Best Resolution |
 1mHz
 |
| Logic Frequency Accuracy |
 +/-(0.06% + 10d)
 |
| Logic Frequency Overload Proection |
 250V
 |
| Linear Frequency Input Range/Sensitivity(True RMS) |
 (200mV/5mV), (2V/50mV), (20V/500mV), (200V/5V)
 |
| Linear Frequency Input Range/Sensitivity(True RMS) |
 (200mV/10mV), (2V/100mV), (20V/10V), (200V/10V)
 |
| Temperature Ranges |
 -30 to 1300 Degrees C (-22 to 2372 Degrees F)
 |
| Temperature Accuracy |
 +/-(1% +2d)
 |
| Duty Cycle Ranges |
 5% to 95%
 |
| Duty Cycle Accuracy |
 +/-10%
 |
| Capacitance Ranges |
 20nF, 200nF, 2μF, 200μF, 2000μF, 20mF, 200mF
 |
| Capacitance Best Resolution |
 10pF
 |
| Capacitance Accuracy |
 +/-(1.2% + 30d) 20nF to 20μF ranges
+/-(2.2% + 30d) 200μF to 20mF ranges
200mF unspecified
 |
| Capacitance Overload Protection |
 250V
 |
| Diode test Test Volt |
 Diode test Test Volt 3V
 |
| Diode test Test Current |
 0.6mA
 |
| Diode test Overload Protection |
 250V
 |
| Continuity Buzzer will sound at |
 <300Ω Resistance
 |
| Continuity Overload Protection |
 250V
 |
| Continuity Safety |
 IEC61010-1CATII 1000V and CATIII 600V
 |
| Dimensions |
 9"(L) x 9.4"(W) x 3.3"(D)
 |
| Weight |
 3.3 lbs
 |
| Power |
 9V NEDA battery or 120V AC @ 60Hz
 |
| Safety |
 CATII 1000V and CATIII 600V
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |