Datasheet: Protek-6500 |
 |
| Protek 6500 Hand Held Multimeter RS232C Interface Description: |
 Protek 6500 Hand Held Multimeter RS232C Interface
is a multimeter that measures frequency, Duty cycle and Capacitance. Protek 6500 features AC and (AC+DC) TRUE RMS measurement. Product Discontinued.
 |
| Protek 6500 Hand Held Multimeter RS232C Interface Characteristics: |
| |
 50,000 count and 50 segment bar graph backlit display
 |
| |
 Basic DC accuracy is +/-0.03 per cent
 |
| |
 RS232 interface with software and cable
 |
| |
 DBm measurement with 4W to 1200W reference resistances
 |
| |
 AC and (AC+DC) TRUE RMS measurement
 |
| |
 Measures frequency, Duty cycle and Capacitance
 |
| |
 Max-Min and Relative measurements
 |
| |
 Auto power off and backlit display
 |
| Protek 6500 Hand Held Multimeter RS232C Interface Specifications: |
| DC mV |
 Ranges 50mV, 500mV
Best Resolution 1μV
Accuracy +/-(0.03 per cent + 6d)
Input Impedance 1GW
 |
| DC Volts |
 Ranges 5V, 50V, 500V, 1000V
Best Resolution 100μV
Accuracy +/-(0.03 per cent + 6d)
Max. Input Voltage 1000V DC
Input Impedance 10MW
 |
| AC mV |
 Ranges 50mV, 500mV
Best Resolution 1μV
AC mV Accuracy 40Hz to 1Khz= +/-(0.5 per cent + 40d), 1KHz to 10KHz= +/-(1.0 per cent + 40d), 10KHz to 20KHz= +/-(2.5per cent + 40d)
Input Impedance 1GW
 |
| AC Volts |
 Ranges 5V, 50V, 500V, 1000V
Best Resolution 100μV
AC Volts Accuracy (5V to 500V ranges) 40Hz to 1KHz= +/-(0.5 per cent +40d), 1KHz to 10KHz= +/-(1.0 per cent + 40d), 10KHz to 20KHz= +/-(2.5 per cent + 40d)
Max. Input Voltage 1000V DC or AC peak
Input Impedance 10MW
 |
| DC μA |
 Ranges 500μA, 5000μA
Best Resolution 10.0nA
Accuracy +/-(0.15 per cent + 1d)
Overload Protection 0.5A-250V fuse
 |
| DC mA |
 Ranges 50mA, 500mA
Best Resolution 1.0μA
Accuracy +/-(0.15 per cent + 10d)
Overload Protection 0.5A-250V fuse
 |
| DC A |
 Ranges 5A, 10A
Best Resolution 100μA
Accuracy +/-(0.5 per cent + 10d)
Overload Protection 10A-250V fuse
 |
| AC μA |
 Ranges 500μA, 5000μA
Best Resolution 10.0nA
Accuracy +/-(0.75 per cent + 10d) 40Hz to 1KHz
Overload Protection 0.5A-250V fuse
 |
| AC mA |
 Ranges 50mA, 500mA
Best Resolution 1.0μA
Accuracy +/-(0.75 per cent + 20d) 40Hz to 1KHz
Overload Protection 0.5A-250V fuse
 |
| AC A |
 Ranges 5A, 10A
Best Resolution 100μA
Accuracy 40Hz to 1KHz 5A= +/-(0.75 per cent + 20d)
40Hz to 1KHz 10A= +/-(0.75 per cent + 20d)
Overload Protection 10A-250V fuse
 |
| Resistance |
 Ranges 500W, 5KW, 50KW, 500KW, 5MW, 50MW
Best Resolution 10.0mW
Accuracy +/-(0.1 per cent + 5d)
Max. Input Voltage 250V
 |
| Continuity Buzzer |
 Buzzer Will sound at < 60W
 |
| Capacitance |
 Ranges 50nF, 500nF, 5μF, 50μF, 500μF, 5000μF
Best Resolution 10pF
Accuracy +/-(1.0 per cent + 5d)
Maximum Input Volts 250V
 |
| Diode Test |
 Range 2.5V
Resolution 0.1mV
Accuracy +/-(1.0 per cent + 5d)
Test Current Approx. 0.7mA
 |
| Logic Frequency |
 Sensitivity +2V to +5V Square wave
Accuracy +/-(0.006 per cent + 4d)
Frequency Range 5Hz to 2MHz
 |
| Frequency |
 Ranges 5Hz to 200KHz
Best Resolution 0.001Hz
Accuracy +/-(0.006 per cent + 4d)
Input Sensitivities (Range-Sensitivity) (500mV - 0.1V), (5V - 0.5V), (50V- 4V), (500V - 40V), (1000V - 400V), (5000μA - 1000μA), (500mA - 100mA)
 |
| Duty Cycle |
 Range 0 to 90 per cent
Resolution 0.01 per cent
Accuracy +/-10 per cent
 |
| General Specifications |
 Operating Temperature 0 to 30 Degrees C (32 to 86 Degrees F) at relative humidity < 80 per cent
31 to 51 Degrees C (87 to 124 Degrees F) at relative humidity < 50 per cent
Power (6) AAA Batteries
Size 7.9" (H) x 3.94" (W) x 1.57" (D)
Weight 1.23 lbs
 |
| Protek 6500 Hand Held Multimeter RS232C Interface Accessories Optional: |
| Accessories |
 Manual, test leads, RS232 cable and software CD
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |