| Datasheet: |
 |
| Fluke Power Analyzer 43B Description: |
 Fluke Power Analyzer 43B (Mfg part No. 1615345) performs the measurements needed to maintain power systems, troubleshoot power problems and diagnose equipment failures. The Fluke 43B power quality analyzer performs trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current.
 |
| Fluke Power Analyzer 43B Characteristics: |
| |
 NiMH Battery provides extended operating time of 6.5 hours
 |
| |
 Combines the most useful capabilities of a power quality analyzer, multimeter and scope
 |
| |
 Calculates 3-phase power on balanced loads, from a single-phase measurement
 |
| |
 Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current
 |
| |
 Monitoring functions help track intermittent problems and power system performance
 |
| |
 Records two selectable parameters for up to 16 days
20 measurement memories to save/recall screens and data with cursor readings
 |
| |
 FlukeView® software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic
 |
| |
 Measures resistance, diode voltage drop, continuity, and capacitance
 |
| |
 Users/applications manual and power quality video to help answer tough questions
 |
| |
 Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
 |
| |
 3 year warranty
 |
| Fluke Power Analyzer 43B Specifications: |
| Input Characteristics: |
 Input impedance 1 MΩ, 20 pF
 |
| |
 Voltage rating 600V rms, CAT III
 |
| V/A/Hz Display: |
 True-rms voltage (ac + dc)
Ranges: 5.000 V, 50.00 V, 500.0 V, 1250 V*
Accuracy: ±(1% + 10 counts)
 |
| |
 True-rms current (ac + dc)
Ranges: 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA
Accuracy: ±(1% + 10 counts)
 |
| |
 Frequency
Ranges: 10.0 to 15.0 kHz
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
 |
| |
 CF Crest factor
Ranges: 1.0 - 10.0
Accuracy: ±(5% + 1 count)
 |
| Power Display: |
 Watts, VA, VAR
1-phase and 3-phase,3 conductor balanced loads
Ranges: 250 W - 1.56 GW
Accuracy: ±(4% + 4 counts) Fundamental Power
Accuracy: ± (2 % + 6 counts) Total Power
 |
| |
 PF Power Factor
Range: 0 - 1.0
Accuracy: ±0.04
 |
| |
 DPF Displacement Power Factor, Cos .F
Range: 0.25 - 0.9
Accuracy: ±0.04
Range: 0.90 - 1.0
Accuracy: ±0.03
 |
| |
 H2 Frequency Fundamental
Ranges: 40.0 to 70.0 Hz
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
 |
| Harmonics Display: |
 Voltage, Current, Frequency
Ranges: Fundamental to 51st harmonic
Accuracy:
Fundamental: VA ±(3% + 2 counts) W ±(5% + 2 counts)
2 to 31st harmonic: VA ±(5% +3 counts) W ±(10% +10 counts)
32 to 51st harmonic: VA ±(15% +5 counts) W ±(30% +5 counts)
 |
| |
 Frequency Fundamental
Ranges: 40 Hz to 70 Hz
Accuracy: ±0.25 Hz
 |
| |
 Phase
Range: V, A (between Fundamental & Harmonics)
Accuracy: ±3º to ±15º
Range: W (between Voltage Fundamental & Current Harmonics)
Accuracy: ±5º to ±15º
 |
| |
 K-factor (Current and Power)
Range: 1.0 to 30.0
Accuracy: ±10%
 |
| |
 THD Total Harmonic Distortion
Range: 0.00 - 99.99
Accuracy: ±(3% + 8 counts)
 |
| Sags and Swells: |
 Recording times: 4 min to 16 days (selectable)
 |
| |
 Vrms Actual, Vrms max, min(AC + DC)
Ranges: 5.000V, 50.00V, 500.0V, 1250V*
Accuracy: Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts)
 |
| |
 Arms Actual, Arms max, min (AC + DC)
Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA
Accuracy: ±(2% +10 counts)
 |
| Transient Capture: |
 Minimum pulse width: 40 ns
 |
| |
 Useful bandwidth input 1: DC to 1 MHz
 |
| |
 Number of transients: 40
 |
| |
 Voltage threshold settings: 20%, 50%, 100%, 200% above or below reference
 |
| |
 Reference signal: After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting.
 |
| |
 Vpeak min, Vpeak max at cursor: 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ±5% of full scale
 |
| R, C, Diode, Continuity: |
 Resistance ranges: 500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ
Resistance accuracy: ±(0.6% + 5 counts)
 |
| |
 Resistance accuracy: ±(0.6% + 5 counts)
 |
| |
 Capacitance ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF
 |
| |
 Capacitance accuracy: ±(2% + 10 counts)
 |
| |
 Diode Ranges: 0 to 3.000 V
 |
| |
 Diode voltage:
Accuracy: ±(2% + 5 counts)
 |
| |
 Continuity: Beeper on at < 30 Ω ± 5 Ω
 |
| |
 Max current: 0.5 mA
 |
| |
 Temperature: °C or °F
 |
| Inrush Current: |
 Inrush times: 1 s, 5 s, 10 s, 50 s, 100 s, 5 min
 |
| |
 Current ranges: 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
 |
| |
 Cursor readings: A peak max at cursor 1 and cursor 2
 |
| |
 Accuracy: ±5% of full scale
 |
| |
 Time between cursors: 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels)
 |
| Temperature (with accessory) |
 Range: -100 °C - 400 °C
Accuracy: ±(0.5% + 5 counts)
 |
| Scope Display: |
 Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor
 |
| |
 Time ranges: 20 ns/div to 60 s/div
 |
| |
 Max sampling rate: 25 MS/s
 |
| |
 Bandwidth
Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads
 |
| |
 Current channel [2]: DC to 15 kHz at inputs, 10 kHz with i400s Current Clamp
 |
| |
 Coupling: AC, DC (10 Hz - 3 dB)
 |
| |
 Vertical sensitivity: 5 mV/div to 500V/div
 |
| |
 Vertical resolution: 8 bit (256 levels)
 |
| |
 Record length: 512 samples per channel
 |
| |
 Base ranges: 60 S/div to 20 nS/div ± (0.4% + 1 pixel
 |
| |
 Timebase modes: Normal, roll, single
 |
| |
 Pre-trigger: Up to 10 divisions
 |
| |
 Trigger Source: Input 1 or Input 2 or automatic selection
 |
| |
 Trigger Mode: Automatic Connect-and-View™, Free Run, and Single Shot
 |
| |
 Connect-and-View™: Advanced automatic triggering that recognizes signal patterns
Automatically adjusts triggering, timebase and amplitude and displays stable pictures
 |
| Memories |
 20 (screens, settings, data)
 |
| Recording: |
 Recording times: 4 min to 16 days (selectable)
 |
| |
 Parameters: Choose one or two parameters from one of the groups below:
Volts/Ampères/Hertz
 |
| |
 Power: Watts, VA, VAR, PF, DPF, Frequency
Harmonics, THD, Volts (Fund. & Harmonic), Amp res (F&H) Watts(F&H)
Frequency (H), %(H) of total, Phase(H), KF
Temperature
 |
| |
 Resistance: Resistance, Diode, Continuity, Capacitance
 |
| |
 Scope: DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor
 |
| Operating Temperature |
 0°C to +50°C
 |
| Electrical Safety |
 EN 61010-1 CAT III, 600V. CSA listed
 |
| Battery Life |
 Rechargeable NiMH pack (charger included), 6.5 hrs extended operating time (continuous
 |
| Shock & Vibration |
 Mil 28800E, Type 3, Class III, Style B
 |
| Case |
 IP51 (dust, drip, waterproof)
 |
| Size |
 232 x 115 x 50 mm
 |
| Weight |
 1.1 kg
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |