My Account Login My Account Login My Account Login View Shopping cart View Shopping cart View Shopping cart Frequently Asked Questions
Go To Homepage Customer Services Customer Services Customer Services International Customers Click here International Customers Click here International Customers Click here
  Electrical Electronic Environmental Fiber Optic HVAC Industrial Laboratory LAN Network Telecom  
  
Follow Testersandtools on FacebookspacerFollow Testersandtools on YouTubespacerValuetesters Newsletters
You are here: Testers and Tools Electrical Power Quality Analyzer Fluke Power Analyzer 43B made by Fluke
Items in shopping cart  
 

    +
+ Accessories
+ Electrical
  +Power Quality Analyzer
+ HVAC

Greenlee-CS-8000-Circuit-Seeker-Circuit-Tracer

Greenlee CS 8000 Circuit Seeker Circuit Tracer
Made by Greenlee


Fluke-FLK-Ti125-Thermal-Imaging-Camera-Industrial-Commercial

Fluke FLK-Ti125 Thermal Imaging Camera
Click here to see Fluke FLK-Ti125 Thermal Imager





Fluke Power Analyzer 43B


more products made by Fluke

Fluke Power Analyzer 43B
Price:$3,399.95
Quantity:

Model Number:
43B


1615345

Manufacturer:
Fluke - see more products

Catalog #: 12947

In Stock. This product normally leaves our warehouse within 1 to 2 business day.

Click here to request a quote   Call for quote 602-795-4033
Call for educational and government discount (602) 795 - 4033

Datasheet:
spacer
Fluke Power Analyzer 43B Description:

Fluke Power Analyzer 43B (Mfg part No. 1615345) performs the measurements needed to maintain power systems, troubleshoot power problems and diagnose equipment failures. The Fluke 43B power quality analyzer performs trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current.
Fluke Power Analyzer 43B Characteristics:
 
NiMH Battery provides extended operating time of 6.5 hours
 
Combines the most useful capabilities of a power quality analyzer, multimeter and scope
 
Calculates 3-phase power on balanced loads, from a single-phase measurement
 
Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current
 
Monitoring functions help track intermittent problems and power system performance
 
Records two selectable parameters for up to 16 days 20 measurement memories to save/recall screens and data with cursor readings
 
FlukeView® software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic
 
Measures resistance, diode voltage drop, continuity, and capacitance
 
Users/applications manual and power quality video to help answer tough questions
 
Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
 
3 year warranty
Fluke Power Analyzer 43B Specifications:
Input Characteristics: 
Input impedance 1 MΩ, 20 pF
 
Voltage rating 600V rms, CAT III
V/A/Hz Display: 
True-rms voltage (ac + dc) Ranges: 5.000 V, 50.00 V, 500.0 V, 1250 V* Accuracy: ±(1% + 10 counts)
 
True-rms current (ac + dc) Ranges: 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA Accuracy: ±(1% + 10 counts)
 
Frequency Ranges: 10.0 to 15.0 kHz Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
 
CF Crest factor Ranges: 1.0 - 10.0 Accuracy: ±(5% + 1 count)
Power Display: 
Watts, VA, VAR 1-phase and 3-phase,3 conductor balanced loads Ranges: 250 W - 1.56 GW Accuracy: ±(4% + 4 counts) Fundamental Power Accuracy: ± (2 % + 6 counts) Total Power
 
PF Power Factor Range: 0 - 1.0 Accuracy: ±0.04
 
DPF Displacement Power Factor, Cos .F Range: 0.25 - 0.9 Accuracy: ±0.04 Range: 0.90 - 1.0 Accuracy: ±0.03
 
H2 Frequency Fundamental Ranges: 40.0 to 70.0 Hz Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
Harmonics Display: 
Voltage, Current, Frequency Ranges: Fundamental to 51st harmonic Accuracy: Fundamental: VA ±(3% + 2 counts) W ±(5% + 2 counts) 2 to 31st harmonic: VA ±(5% +3 counts) W ±(10% +10 counts) 32 to 51st harmonic: VA ±(15% +5 counts) W ±(30% +5 counts)
 
Frequency Fundamental Ranges: 40 Hz to 70 Hz Accuracy: ±0.25 Hz
 
Phase Range: V, A (between Fundamental & Harmonics) Accuracy: ±3º to ±15º Range: W (between Voltage Fundamental & Current Harmonics) Accuracy: ±5º to ±15º
 
K-factor (Current and Power) Range: 1.0 to 30.0 Accuracy: ±10%
 
THD Total Harmonic Distortion Range: 0.00 - 99.99 Accuracy: ±(3% + 8 counts)
Sags and Swells: 
Recording times: 4 min to 16 days (selectable)
 
Vrms Actual, Vrms max, min(AC + DC) Ranges: 5.000V, 50.00V, 500.0V, 1250V* Accuracy: Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts)
 
Arms Actual, Arms max, min (AC + DC) Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy: ±(2% +10 counts)
Transient Capture: 
Minimum pulse width: 40 ns
 
Useful bandwidth input 1: DC to 1 MHz
 
Number of transients: 40
 
Voltage threshold settings: 20%, 50%, 100%, 200% above or below reference
 
Reference signal: After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting.
 
Vpeak min, Vpeak max at cursor: 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ±5% of full scale
R, C, Diode, Continuity: 
Resistance ranges: 500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ Resistance accuracy: ±(0.6% + 5 counts)
 
Resistance accuracy: ±(0.6% + 5 counts)
 
Capacitance ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF
 
Capacitance accuracy: ±(2% + 10 counts)
 
Diode Ranges: 0 to 3.000 V
 
Diode voltage: Accuracy: ±(2% + 5 counts)
 
Continuity: Beeper on at < 30 Ω ± 5 Ω
 
Max current: 0.5 mA
 
Temperature: °C or °F
Inrush Current: 
Inrush times: 1 s, 5 s, 10 s, 50 s, 100 s, 5 min
 
Current ranges: 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
 
Cursor readings: A peak max at cursor 1 and cursor 2
 
Accuracy: ±5% of full scale
 
Time between cursors: 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels)
Temperature (with accessory) 
Range: -100 °C - 400 °C Accuracy: ±(0.5% + 5 counts)
Scope Display: 
Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor
 
Time ranges: 20 ns/div to 60 s/div
 
Max sampling rate: 25 MS/s
 
Bandwidth Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads
 
Current channel [2]: DC to 15 kHz at inputs, 10 kHz with i400s Current Clamp
 
Coupling: AC, DC (10 Hz - 3 dB)
 
Vertical sensitivity: 5 mV/div to 500V/div
 
Vertical resolution: 8 bit (256 levels)
 
Record length: 512 samples per channel
 
Base ranges: 60 S/div to 20 nS/div ± (0.4% + 1 pixel
 
Timebase modes: Normal, roll, single
 
Pre-trigger: Up to 10 divisions
 
Trigger Source: Input 1 or Input 2 or automatic selection
 
Trigger Mode: Automatic Connect-and-View™, Free Run, and Single Shot
 
Connect-and-View™: Advanced automatic triggering that recognizes signal patterns Automatically adjusts triggering, timebase and amplitude and displays stable pictures
Memories 
20 (screens, settings, data)
Recording: 
Recording times: 4 min to 16 days (selectable)
 
Parameters: Choose one or two parameters from one of the groups below: Volts/Ampères/Hertz
 
Power: Watts, VA, VAR, PF, DPF, Frequency Harmonics, THD, Volts (Fund. & Harmonic), Amp res (F&H) Watts(F&H) Frequency (H), %(H) of total, Phase(H), KF Temperature
 
Resistance: Resistance, Diode, Continuity, Capacitance
 
Scope: DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor
Operating Temperature 
0°C to +50°C
Electrical Safety 
EN 61010-1 CAT III, 600V. CSA listed
Battery Life 
Rechargeable NiMH pack (charger included), 6.5 hrs extended operating time (continuous
Shock & Vibration 
Mil 28800E, Type 3, Class III, Style B
Case 
IP51 (dust, drip, waterproof)
Size 
232 x 115 x 50 mm
Weight 
1.1 kg



Need Technical Advise? Please Call: 602-795-4033


Browse Similar Products
Related Products
Products
AEMC 3945-MR193 Powe.. Extech 382090 1000A .. Amprobe DM-4 Power Q..
AEMC 3945-MR193 PowerPad Power Quality Analyzer with MR193 clamps - AEMC Extech 382090 1000A 3-Phase Power Quality Analyzer - Extech Amprobe DM-4 Power Quality Recorder Analyzer - Amprobe
  • AEMC 3945-MR193 PowerPad Power Quality Analyzer with MR193 clamps - AEMC
  • $ 4,195.00   more info...
  • Extech 382090 1000A 3-Phase Power Quality Analyzer - Extech
  • $ 2,249.00   more info...
  • Amprobe DM-4 Power Quality Recorder Analyzer - Amprobe
  • $ 0.00   more info...
AEMC 8220 MN193-BK P.. Ideal Industries 61-.. Amprobe DM-III Digit..
AEMC 8220 MN193-BK Power Quality Analyzer - AEMC Ideal Industries 61-830 Voltage Performance Monitor - Ideal Industries Amprobe DM-III Digital Power Quality Recorder - Amprobe
  • AEMC 8220 MN193-BK Power Quality Analyzer - AEMC
  • $ 1,169.00   more info...
  • Ideal Industries 61-830 Voltage Performance Monitor - Ideal Industries
  • $ 543.18   more info...
  • Amprobe DM-III Digital Power Quality Recorder - Amprobe
  • $ 0.00   more info...
AEMC 8230 SR193-BK S.. AEMC 8220 193-24-BK .. Fluke N4K 3PP50I Nor..
AEMC 8230 SR193-BK Single-Phase Power Quality Analyzer - AEMC AEMC 8220 193-24-BK Power Quality Analyzer - AEMC Fluke N4K 3PP50I Norma-4000 Precision Power Analyzer 3108583 - Fluke
  • AEMC 8230 SR193-BK Single-Phase Power Quality Analyzer - AEMC
  • $ 1,995.00   more info...
  • AEMC 8220 193-24-BK Power Quality Analyzer - AEMC
  • $ 1,229.00   more info...
  • Fluke N4K 3PP50I Norma-4000 Precision Power Analyzer 3108583 - Fluke
  • $ 19,599.95   more info...


Secure Shop provided by Biggiweb Internet Solutions, Inc.
Positive SSL on a transparent background
Testers and Tools Electrical Power Quality Analyzer Fluke Power Analyzer 43B made by Fluke
  Electrical Electronic Environmental Fiber Optic HVAC Industrial Laboratory LAN Network Telecom  
 

Site Map

Find products :


 
We Accept AmericanExpress-Amex-Discover-Card-MasterCard-Visa-Creditcards.
Customer Service, please call 602-795-4033 • Fax: 602-795-4624  • sales@testersandtools.com
© 2014 Testers and Tools, All rights reserved.