Datasheet: Fluke-87V |
 |
| Fluke 87V Industrial Multimeter Description: |
 Fluke 87V Industrial Multimeter (Mfg part No. 2074974)has improved measurement functions, trouble-shooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution and electro-mechanical equipment.

Fluke 87V industrial multimeter features built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument.
 |
| Fluke 87V Industrial Multimeter Characteristics: |
| Virtual Product Demo |
 Clamp Meter Demo
 |
| |
 Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
 |
| |
 Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
 |
| |
 Large digit display with bright, two-level backlight
 |
| |
 True-rms ac voltage and current for accurate measurements on non linear signals
 |
| |
 Selectable filter for accurate voltage and frequency measurements on motor drives
 |
| |
 6000 counts, 3-3/4 digits
 |
| |
 4-1/2 digit mode for precise measurements (20,000 counts)
 |
| |
 Measure up to 1000 V ac and dc
 |
| |
 Measure up to 10 A, 20 A for up to 30 seconds
 |
| |
 Frequency to 200 kHz and % duty cycle
 |
| |
 Resistance, continuity and diode test
 |
| |
 10,000 μF capacitance range for components and motor caps
 |
| |
 Min/Max-Average recording with Min/Max Alert to capture variations automatically
 |
| |
 Peak capture to record transients as fast as 250 μs
 |
| |
 Relative mode to remove test lead interference from low ohms measurements
 |
| |
 Auto and manual ranging for maximum flexibility
 |
| |
 Touch Hold to capture stable readings avoiding noisy signals
 |
| |
 Analog bargraph for fast changing or unstable signals
 |
| |
 Input Alert provides audible warning against wrong use of input jacks
 |
| |
 Improved selectable sleep mode for long battery life
 |
| |
 Access door for fast battery changes without breaking the calibration seal
 |
| |
 "Classic" design with new removable holster with built in test lead and probe storage
 |
| |
 Lifetime warranty
 |
| Fluke 87V Industrial Multimeter Specifications: |
| Voltage DC |
 Maximum Voltage: 1000V
Accuracy: +/-(0.05%+1)
Maximum Resolution: 10 μV
 |
| Voltage AC |
 Maximum Voltage: 1000V
Accuracy: +/-(0.7%+2) True RMS
AC Bandwidth: 20kHz*
*with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV
 |
| Current DC |
 Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: +/-(0.2%+2)
Maximum Resolution: 0.01 μA
 |
| Current AC |
 Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: +/-(1.0%+2) True RMS
Maximum Resolution: 0.1 μA
 |
| Resistance |
 Maximum Resistance: 50 MΩ
Accuracy: +/-(0.2%+1)
Maximum Resolution: 0.1Ω
 |
| Capacitance |
 Maximum Capacitance 9,999 μF
Accuracy +/-(1%+2)
Maximum Resolution 0.01 nF
 |
| Frequency |
 Maximum Frequency 200 kHz
Accuracy +/-(0.005%+1)
Maximum Resolution 0.01 Hz
 |
| Duty Cycle |
 Maximum Duty Cycle 99.9%
Accuracy +/-(0.2% per khz +0.1%)
Maximum Resolution 0.1%
 |
| Temperature Measurement |
 -200.0 to 1090 Degrees C
-328.0 to 1994.0 Degrees F
excluding probe
 |
| 80 BK Temperature Probe |
 -40.0 to 260 Degrees C
-40.0 to 500 Degrees F, 2.2 Degrees C or 2% whichever is greater
 |
| Conductance |
 Maximum Conductance 60.00 nS
Accuracy +/-(1.0%+10)
Maximum Resolution 0.01 nS
 |
| Diode |
 Range: 3 V
Resolution: 1 mV
Accuracy: +/-(2 % + 1)
 |
| Duty Cycle Range |
 Accuracy: Within +/-(0.2% per kHz + 0.1 %)
 |
| Operating Temperature |
 -20 to +55 Degrees C
 |
| Storage Temperature |
 -40 to +60 Degrees C
 |
| Humidity (Without Condensation) |
 0% - 90% (0 to 35 Degrees C)
0% - 70% (35 to 55 Degrees C)
 |
| Operating Altitude |
 2000 m
 |
| Overvoltage category |
 EN 61010-1 to 1000 V CAT III, 600V CAT IV
 |
| Agency Approvals |
 UL, CSA, TUV, VDE listed
 |
| Size |
 201 x 98 x 52 mm (with holster)
 |
| Weight |
 355 g
 |
| Weigh With Holster and Flex-Stand |
 624 g
 |
| Display |
 Digital: 6000 counts updates 4/sec.
(19,999 counts in high-resolution mode.)
Analog: 32 segments, updates 40/sec.
Frequency: 19,999 counts, updates 3/sec at > 10 Hz.
 |
| Battery Life |
 Alkaline: ~400 hours typical, without backlight
 |
| Shock |
 1 Meter drop per IEC 61010-1:2001
 |
| Vibration |
 Per MIL-PRF-28800 for a Class 2 instrument
 |

Need Technical Advise? Please Call: 602-795-4033