Datasheet: Bacharach-PCA3-235 |
 |
| Bacharach PCA3 235 Combustion Analyzer 24-8441 Description: |
 Bacharach PCA3 235 Combustion Analyzer 24-8441 is the definitive combustion and emissions analyzer that enables fast and accurate measurement for on-demand or semicontinuous sampling of light industrial, institutional, commercial and residential furnaces, boilers and appliances. Measures 3 Gases: O2, CO, NO.

Bacharach PCA3 235 Combustion Analyzer 24-8441 features superbright backlighting, zoom display feature and dimming mode function to provide users with best-in-class instrumentation. Made in the USA. Free ground shipping within continental US.
 |
| Bacharach PCA3 235 Combustion Analyzer 24-8441 Applications: |
| |
 Light industrial, institutional, commercial and residential furnaces, boilers and appliances
 |
| Bacharach PCA3 235 Combustion Analyzer 24-8441 Characteristics: |
| Includes: |
 12 inches Probe Assembly, Protective Boot w/Magnet, Fyrite User Software, USB Cable, Replacement Filter Element (pkg. of 3), 4 AA Alkaline Batteries and Hard Carrying Case
 |
| Measures and displays: |
 Flue gas oxygen, carbon monoxide, stack temperature, combustion air
temperature, draft and differential pressure
 |
| |
 Superbright backlighting
 |
| |
 Zoom display
 |
| |
 New battery-saving dimming mode
 |
| |
 Unique B-Smart pre-calibrated sensors & exchange program
 |
| |
 Logo upload with company information and tag customer information to test data for custom reports
 |
| |
 Sturdy metal gas and draft connectors
 |
| |
 Ten fuel choices plus the ability to load custom fuels
 |
| |
 Ability to store and download 1000 test records
 |
| |
 Multilingual display and options for European calculations
 |
| |
 Loss and efficiency are calculated from standard
heat-loss calculations
 |
| |
 O2, CO/H2 compensated, NO sensors
 |
| Model comparison: |
 Bacharach Combustion Analyzer Comparison Table
 |
| Bacharach PCA3 235 Combustion Analyzer 24-8441 Benefits: |
| |
 Analyzer Functionality, Smart Sensors, Graphic Display, and Rugged Design and Construction.
 |
| |
 Bacharach's unique B-Smart Sensor Exchange Program will deliver new B-Smart Sensors right to the user. Just a simple "pop out and pop in" replacement of the sensor permits self calibration with no gas or guess work required! Providing the quickest and easiest calibration options to date, the B-Smart Sensors assures accurate performance with no downtime.
 |
| Bacharach PCA3 235 Combustion Analyzer 24-8441 Specifications: |
| Weight |
 1.4 lbs; 0.6 kg
 |
| Dimensions |
 9 x 3 x 2.5 in;
22.9 x 7.6 x 6.3 cm
 |
| Display |
 Full Color Graphic Display 320 x 240 pixels
 |
| Warm Up Time |
 60 Second Total Warm Up Time- sensors are checked and autozeroed during warm up
 |
| Power Source |
 Four Disposable AA Alkaline Batteries. Optional Universal AC Adapter 100 to 240 Volts at 47 to 63 Hz
 |
| Selectable Fuels |
 Natural Gas, Oil #2, Oil #4, Oil #6, Propane, Coal, Wood, Kerosene, Bagasse and Digester Gas
 |
| Operating Humidity Range |
 15 to 90 percent RH Non-condensing
 |
| Operating Temperature Range |
 32 to 104 F; 0 to 40 C
 |
| User Interface |
 Full Color Graphic Display (320 x 240 pixels), Optional Infrared Printer
 |
| Body Materials |
 Durable ABS Housing/Rugged Rubberized Over-molding and Protective Boot w/Magnet
 |
| Logged Memory |
 500 Complete Logged Combustion Test Records
 |
| Memory |
 500 Complete Combustion Test Records
 |
| Accuracy |
 Oxygen: plus/minus 0.3 percent O2 (Flue Gas)
Stack Temperature: plus/minus 4°F between 32 and 255°F; plus/minus 2 C between 0 and 124 C
plus/minus 6 F between 256 and 480 F;
plus/minus 3 C between 125 and 249 C
plus/minus 8 F between 481 and 752 F;
plus/minus 4 C between 250 and 400 C
Primary-air/Ambient Temperature: plus/minus 2 F between 32 and 212 F; plus/minus 1 C between 0 and 100 C )
Pressure/Draft: plus/minus 2 percent Reading or 0.02 inwc minus 1 to 10 inwc
plus/minus 3 percent of Reading between plus/minus minus 40 and plus/minus 40 inwc
CO: plus/minus 5 percent of Reading or plus/minus 10 ppm in the range of 0-2000 ppm CO
plus/minus 10 percent of Reading between 2001 to 4,000 ppm
NO: plus/minus 5 percent of Reading or plus/minus 5 ppm whichever is greater between 0 to 2000 ppm NO
 |
| Calculated Ranges |
 Combustion Efficiency: 0.1 to 100 percent
Excess Air: 1.0 to 250 percent
Carbon Dioxide (Dry Basis): 0 to Fuel Dependent Maximum
CO referenced to percent O2: 0 to 9,999 ppm
NO referenced to percent O2: 0 to 9,999 ppm
 |
| Measurement Ranges |
 Primary/Ambient Air Temperature: minus 4 to 999 F
Stack Temperature: minus 4 to 2192 F
Oxygen: 0 to 20.9 percent
Carbon Monoxide (H2 Compensated): 0 to 4,000 ppm
Nitric Oxide: 0 to 3,000 ppm
Pressure/Draft: minus 72 to plus 72 inwc
 |

Need Technical Advise? Please Call: 602-795-4033