Datasheet: 5XP-A |
 |
| Amprobe 5XP-A Digital Multimeter Description: |
 Amprobe 5XP-A Digital Multimeter is your meter for residential, commercial and general troubleshooting applications. Voltec non-contact voltage detection lets you instantly detect dangerous ac line voltages. Amprobe 5XP-A has a triple safety rating protecting you against line surges and overvoltage conditions. Easier and more efficient in field service, electronic repair, electrical and HVAC applications.
 |
| Amprobe 5XP-A Digital Multimeter Characteristics: |
| |
 27 ranges/10 functions - A complete performance, general purpose digital multimeter
 |
| |
 VolTect Non-Contact Voltage Detector lets you instantly identify dangerous AC voltage
 |
| |
 Magne-Grip holster with magnetic strap frees both hands for work
 |
| |
 2000-count 3-1/2 digit display
 |
| |
 750 V ac/ 1000 V dc - Highest voltage rating in this class of meter
 |
| |
 Resistance and continuity for troubleshooting bad connections
 |
| |
 Battery load test with 1.5 volt and 9 volt capabilities
 |
| |
 Min/Max records minimum and maximum values
 |
| |
 Data Hold freezes display to "hold" measurement reading
 |
| |
 MSRP $39.95 (US)
 |
| Amprobe 5XP-A Digital Multimeter Specifications: |
| DC Current |
 Ranges 200 μA, 2 mA, 20 mA, 200 mA
Resolution 0.1 μA
Accuracy +/-(1.5 % rdg + 1 dgt)
Input protection 315 mA/1000 V fast blow ceramic fuse 6.3 x 32 mm on mA input
Burden voltage 300 mV max. (1 V max. on 200 mA range)
 |
| AC Current (45 Hz - 500 Hz) |
 Ranges 200 μA, 2 mA, 20 mA, 200 mA
Resolution 0.1 μA
Accuracy +/-(2.0 % rdg + 5 dgts)
Input protection 315 mA/1000 V fast blow ceramic fuse 6.3 x 32 mm on mA input
Burden voltage 300 mV max. (1 V max. on 200 mA range) voltage
 |
| Resistance |
 Audible indication 75 Ω +/- 25 Ω
Response time 100 ms
Overload protection 1000 VDC or 750 VAC rms
Resolution 100 mΩ
Accuracy on 200 Ω to 200 kΩ ranges +/-(1.0 % rdg + 4 dgts)
Accuracy on 2 MΩ ranges +/-(1.5 % rdg + 4 dgts)
Accuracy on 20 MΩ range +/-(2.0 % rdg + 5 dgts)
Open circuit volts 0.3 Vdc typical, (3.0 Vdc on 200 Ω range)
Overload protection 1000 VDC or 750 VAC RMS
 |
| Input protection |
 315 mA/1000 V fast blow ceramic fuse 6.3 x 32 mm on mA input
 |
| Diode Test |
 Test current 1.0 mA (approximate)
Accuracy +/-(1.5 % rdg + 3 dgts)
Resolution 1 mV
Open circuit volts 3.0 Vdc typical
Overload protection 1000 VDC or 750 VAC rms
 |
| Battery Test |
 Ranges 1.5 V, 9 V
Resolution 1 mV, 10 mV
Accuracy +/-(3.5 % rdg + 2 dgts)
Loaded current 150 mA typical for 1.5 V range, 5 mA typical for 9 V range
Overload protection 1000 VDC or 750 VAC rms on 9 V range, on VΩ input315 mA/1000 V fast blow ceramic fuse on 1.5 V range, on mA input
Non-Contact Voltage Indicator Sense voltage 70 V to 600 VAC beeper chirps and big bright red LED comes on, works on all ranges
 |
| Display |
 3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999
 |
| Polarity |
 Automatic, positive implied, negative polarity indication
 |
| Overrange |
 (OL) or (-OL) is displayed
 |
| Zero |
 Automatic
 |
| Low battery indication |
 The battery icon is displayed when the battery voltage drops below the operating level
 |
| Measurement rate |
 2.5 times per second, nominal
 |
| Operating environment |
 0 to 50 Degrees C at <70 % R.H.
 |
| Storage temperature |
 -20 to 60 Degrees C, 0 to 80 % R.H. with battery removed from meter
 |
| Accuracy |
 Stated accuracy at 23 Degrees C +/- 5 Degrees C, <75 % relative humidity
 |
| Temperature coefficient |
 0.1 x (specified accuracy) per Degree C (0 to 18 Degrees C, 28 to 50 Degrees C)
 |
| Altitude |
 6561.7 feet (2000 M)
 |
| Power |
 Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
 |
| Battery life |
 200 hours typical with carbon-zinc
 |
| Dimensions |
 155 mm (H) x 72 mm (W) x 32 mm (D)
 |
| Weight |
 Approx. 210 g including battery
 |
| Safety |
 Designed to meet IEC 1010-1, Rev-2 CAT I 1000 V, CAT II 600 V,CAT III 300 V, class 2 and pollution deg. 2 indoor use. Complies with CE,and CSA 22.2 No. 1010-1 requirements.
 |
| Auxiliary Features |
 Min/Max Records the maximum reading in a measurement, records the minimumreading in a measurementData hold Freeze the latest reading on the displaymA jack Input warning detects wrong connection
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |