Datasheet: 8230-193-24-BK-AEMC |
 |
| AEMC 8230 193-24-BK Single Phase Power Quality Analyzer Description: |
 AEMC 8230 193-24-BK Single Phase Power Quality Analyzer is a single-phase power quality analyzer that is easy-to-use, compact and shock-resistant. It is intended for technicians and engineers to measure and carry out diagnostic work and power quality work on single- or three-phase balanced load networks. Users are able to obtain instant waveforms of an electrical network’s principal characteristics, and also monitor their variation over a period of time.

The multi-tasking measurement system simultaneously handles all the measurement functions and waveform display of the various magnitudes, detection, continuous recordings and their display without any constraints.

This particular model comes with 10 to 6500A AmpFlex clamp current probe.
 |
| AEMC 8230 193-24-BK Single Phase Power Quality Analyzer Applications: |
| |
 Motor start-up analysis
 |
| |
 Verification of power distribution circuits
 |
| |
 Measurement and recording of power system quality (kW, VA, VAR)
 |
| |
 Energy metering (kVAh, VARh, kWh)
 |
| |
 In-plant troubleshooting of power distribution panels and individual machinery
 |
| |
 Determine harmonic problems originating from source or load
 |
| AEMC 8230 193-24-BK Single Phase Power Quality Analyzer Characteristics: |
| |
 Captures up to 4096 alarm events using up to 10 different thresholds
 |
| |
 Displays and records up to 17 different power quality parameters
 |
| |
 Download stored data to DataView® software via optical with isolated USB port
 |
| |
 Configurable from DataView® software or front panel
 |
| |
 Stores up to 1MB of trend recorded data
 |
| |
 Stores up to eight screen captures
 |
| |
 Captures, displays and stores inrush current waveforms and statistics
 |
| |
 Displays individual harmonic values and % for Volts and Amps through the 50th harmonic
 |
| |
 Displays total harmonic distortion (THD-F and THD-R) for voltage and current
 |
| |
 Calculates and displays Watts, VARs and VA, Power Factor and Displacement Power Factor for single-phase and balanced three-phase
 |
| |
 Displays Min, Max and Average Volts and Amps, Crest Factor, Peak value and K-Factor
 |
| |
 Measures up to 660Vrms or VDC
 |
| |
 Measures up to 6500AAC or 1400ADC (probe dependent)
 |
| |
 Includes DataView® software FREE
 |
| AEMC 8230 193-24-BK Single Phase Power Quality Analyzer Features: |
| Power: |
 NiMH AA rechargable battery pack; AC Supply: 110/230V (50/60Hz)
 |
| Display: |
 1/4 VGA (320x240) color LCD
 |
| Dimensions: |
 8.3x4.3x2.4" (211x108x60mm)
 |
| Weight: |
 1.9 lbs (0.88kg)
 |
| Safety: |
 EN 61010, CAT III 600V, CE approved, Pollution Degree 2
 |
| Communication Port: |
 Optically isolated USB
 |
| Safety Rating: |
 EN61010, 600V Cat.III, Pollution Degree 2
 |
| AEMC 8230 193-24-BK Single Phase Power Quality Analyzer Specifications: |
| Sampling Frequency: |
 256 samples/cycle
 |
| Data Storage: |
 1.5MB partitioned for waveforms, alarms and trend recording
 |
| Voltage (TRMS): |
 Phase-to-Phase 660V; Phase-to-Neutral 600V
 |
| Current (TRMS): |
 MN Clamp: 5mA to 100mA/120A or 2 to 240A; MR Clamp: 10 to 1000A AC, 10 to 1400A DC; SR Clamp: 3 to 1200A; AmpFlex Clamps: 10 to 6500A
 |
| Frequency: |
 40 to 70Hz
 |
| Other Measurements: |
 KW, kVAR, PF, DPF, kWh, kVARh, kVAh, K-Factor, Flicker, Harmonic Phase Shift, Phase Rotation
 |
| Harmonics: |
 THD-R, THD-F, V, A, VA, 1st to 50th, Direction, Sequence
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |